2
T1 T2
ENCSER
V
IN
G
N
D
C
1
UP
DW
C
2
I1
I2
I3
I4
I5
I6
I7
I8
AA
AR
I9
Serial outputs
VEGA
C
3
DL3
Led DL3: Inputs diagnostic:
It turns on when an input is activated
TECHNICAL DATA:
Power Supply
12/24 Vac/dc
Board dimensions
67x100x22 mm
Weight
77g
Working mode
One wire per floor, binary code, inverted binary code,
gray code.
Programming
The programming is done using two push buttons T1 e
T2 which the board is equipped and a serial display
Activation of the arrows
Common anode or common cathode
Activation of the alarm/signalling
Common anode or common cathode
Activation of the inputs
Common anode or common cathode
Inputs working range
12 a 120 Vac/dc ± 10%
Serial outputs
Serial VEGA (ENCSER_VEG)
Mounting
By DIN
Temperature working range
From -20 to 50 °C
Available inputs
9 (up to 33 with ENCSER_EXP expansion boards)
ENCSER programming is made through T1 e T2, push buttons using a VEGA serial display.
Allows to select;
-the type of decoding (1 wire per floor, binary code, inverted binary code or gray code);
-the first floor (the other floor values will be automatically shifted);
-the number of expansion (ENCSER_EXP) connected (up to 3)
PINOUT
PIN
DESCRIPTION
VIN
Power Supply (+)
GND
Power Supply (-)
C1
Arrows common
UP
Up arrow
DW
Down arrow
C2
Inputs common
(I1-I9)
I1
Input 1
I2
Input 2
I3
Input 3
I4
Input 4
I5
Input 5
I6
Input 6/
Maintenance
I7
Input 7/ Overload
I8
Input 8/ Gong
I9
Input 9/
Out of service
C3
Alarms common
AA
Alarm active
AR
Alarm received