background image

 

T1 T2

ENCSER

V

IN

G

N

D

C

1

UP

DW

C

2

I1

I2

I3

I4

I5

I6

I7

I8

AA

AR

I9

Serial outputs

VEGA

C

3

DL3

Led DL3: Inputs diagnostic:
It turns on when an input is activated

 

TECHNICAL DATA: 

 

Power Supply 

12/24 Vac/dc 

Board dimensions 

67x100x22 mm 

Weight 

77g 

Working mode 

One wire per floor, binary code, inverted binary code, 
gray code. 

Programming 

The programming is done using two push buttons T1 e 
T2 which the board is equipped and a serial display 

Activation of the arrows 

Common anode or common cathode 

Activation of the alarm/signalling 

Common anode or common cathode 

Activation of the inputs 

Common anode or common cathode 

Inputs working range 

12 a 120 Vac/dc ± 10% 

Serial outputs 

Serial VEGA (ENCSER_VEG)  

Mounting 

By DIN 

Temperature working range 

From -20 to 50 °C 

Available inputs 

9 (up to 33 with ENCSER_EXP expansion boards) 

 
ENCSER programming is made through T1 e T2, push buttons using a VEGA serial display. 
Allows to select; 
-the type of decoding (1 wire per floor, binary code, inverted binary code or gray code); 
-the first floor (the other floor values will be automatically shifted); 
-the number of expansion (ENCSER_EXP) connected (up to 3) 

PINOUT 

PIN 

DESCRIPTION 

VIN 

Power Supply (+) 

GND 

Power Supply (-) 

C1 

Arrows common 

UP 

Up arrow 

DW 

Down arrow 

C2 

Inputs common 
(I1-I9) 

I1 

Input 1 

I2 

Input 2 

I3 

Input 3  

I4 

Input 4 

I5 

Input 5 

I6 

Input 6/ 
Maintenance 

I7 

Input 7/ Overload 

I8 

Input 8/ Gong 

I9 

Input 9/  
Out of service 

C3 

Alarms common 

AA 

Alarm active 

AR 

Alarm received 

Summary of Contents for ENCSER

Page 1: ...REV N 01 HARDWARE 2 0 FRW 0 5B PROGRAMMING MENU ENCSER ENCSER_EXP ENCSER_EXP ENCSER_EXP...

Page 2: ...1 INDEX TECHNICAL DATA 2 PINOUT 2 APPLICATION DRAWINGS 3 MENU SUMMARY Errore Il segnalibro non definito ENCSER_EXP 8 DECLARATION OF CONFORMITY Errore Il segnalibro non definito...

Page 3: ...uts working range 12 a 120 Vac dc 10 Serial outputs Serial VEGA ENCSER_VEG Mounting By DIN Temperature working range From 20 to 50 C Available inputs 9 up to 33 with ENCSER_EXP expansion boards ENCSER...

Page 4: ...per floor Binary code Inverted binary code Bcd code Gray code USCITA Internal serial External serial SERCAR_LCD_03 Floor 0 Floor 1 Floor n LCD601 LCD601 LCD601 CEX 20 KE CL CEX 20 KE CL External seri...

Page 5: ...ND C1 UP DW C2 I1 I2 I3 I4 I5 I6 I7 I8 AA AR I9 C3 12 24 Vac dc CONTROL BOARD OUTPUTS 12 120 Vac dc ENCSER application diagram with common cathode T1 T2 ENCSER VIN GND C1 UP DW C2 I1 I2 I3 I4 I5 I6 I7...

Page 6: ...8 ON ON ON OFF ON 9 ON OFF OFF ON OFF 9 OFF ON ON OFF ON 10 OFF ON OFF ON OFF 10 ON OFF ON OFF ON 11 ON ON OFF ON OFF 11 OFF OFF ON OFF ON 12 OFF OFF ON ON OFF 12 ON ON OFF OFF ON 13 ON OFF ON ON OFF...

Page 7: ...N OFF OFF OFF 1 OFF ON ON OFF OFF 2 ON ON ON OFF OFF 3 ON OFF ON OFF OFF 4 OFF OFF ON OFF OFF 5 OFF OFF ON ON OFF 6 ON OFF ON ON OFF 7 ON ON ON ON OFF 8 OFF ON ON ON OFF 9 OFF ON OFF ON OFF 10 ON ON O...

Page 8: ...9 Out of service Press the T2 ENTER button to confirm the desired value The programming procedure is completed and the data are stored Menu 5 Allows to activate the function memorize floor Press five...

Page 9: ...The values visualized at the other floors will be automatically worked out by the board 3 0 3 0 Enables the expansions number ENCSER_EXP max 3 4 0 1 1 Enable the input for overload gong and out of ser...

Page 10: ...I5 I6 I7 I8 I1 ENCSER_EXP 3 I2 I3 I4 I5 I6 I7 I8 I1 NOTE Floor no Visualized with default settings menu 2 1 PIN C2 is the common of the ENCSER_EXP inputs PIN ENCSER_EXP 3 I1 INPUT 26 24 I2 INPUT 27 2...

Page 11: ...10...

Page 12: ...11 Vega Srl Via degli Appennini 11 13 Capparuccia 63845 Ponzano di Fermo AP Italy P Iva 01578140442 Tel 39 0734 631941 Interno 1 Fax 39 0734 636098 Interno assistenza 39 0734 275406 www vegalift it...

Reviews: