Vega SI-22 / User Manual
24
Revision 08 – 15 September 2020
“VEGA SI-22” TAB
The “Vega SI-22” tab contains the settings of the connected device.
Current state
– displays the current parameters of the device - the number of counted
pulses at the inputs, the external thermistor temperature, and the battery level.
To reset the pulse count at the inputs, it is necessary to put the device in the "Storage"
mode by pressing the button on the board for a long time (more than 5 seconds) (see section
"Initial startup").
Input settings
– allows setting up the current mode of inputs from pulse to guard
mode and back. When transferring the input to the security mode, the device will send an
alarm packet to the network (see part 5, packet 2) whenever this input is triggered. The
maximum possible frequency of alarm packets generation is one per second. Here you can
set the values of the high and low temperature thresholds.