Event Details
10.1.8 Tandem Connection Monitoring (TCM)
HP Setup
TCM Standards
The Tandem paths are defined in ITU recommendation G.707 Annex D and Annex E
G.707 Annex D for VC4 and VC3
G.707 Annex E for VC2 and VC1
G.707 defines a tandem connection source and sink and describes the responses of each when defect
(alarm) and error conditions are detected
Tandem connection maintenance signals are carried in:
N1 byte for VC4 and VC3
N2 byte for VC2 and VC
These two bytes are structured similarly, but their functions are not identical