SDH Error Type
8.2.3 OTN Errors
OTU-1/2 signals
: FAS, MFAS, BIP, BEI, Corrected FEC errors, Uncorrectable FEC
ODU-1/2 signals
: BIP, BEI
STM-16/64 signals:
FAS, B1, B2, MS-REI, B3, HP-REI, LP-BIP, LP-REI,
Depends on payload:
2M-FAS, 2M-CRC, 2M-REI, 34M-FAS, 45M-FAS, 1.5M-FAS
OTN Error Type
Error Flow:
OTN, SDH, SONET, PDH signals
Injects different anomalies into the transmit signal. Error insertion flow modes include:
Single:
Inserts a single error every time the insertion button is tapped
Count:
Specific count or number of errors when the insertion button is tapped
Rate:
Specific rate between 1x10
-3
and 5x10
-6
The list of available error types depends on the type of framing being used and the SDH or PDH hierarchies and line
interfaces that have been selected.