7. Alarms Screen

When an alarm condition exists, the information is sent from the engine

and/or transmission, the information will be displayed via alarm icons,

LEDs, and internal alarm buzzer (and external if connected). 

To acknowledge the alarm press Key 4 to acess alarm screen and then

Key 3 to silence the alarm. Pressing Key 4 again will exit alarm screen.
The alarm icons and LEDs will continue to flash until the alarm condition

is resolved and alarm clear command is received from the engine and/or

transmission.

Check Engine - Alarm will sound along with Orange LEDs.

Stop Engine - Alarm will sound along with Red LEDs.

Summary of Contents for VeeCAN 128

Page 1: ...VeeCAN 128 VeeCAN Veethree Engine Monitor TM ...

Page 2: ...mission data Please read through the guide before use The VEM software creates graphical instrument clusters to display parameters and alarms providing users with a timesaving solution for introducing equipment incorporating higher degrees of electronic display We hope that you will be pleased with this product and that you will have many years of trouble free operation If you have any problems or...

Page 3: ...VeeCAN 128 Connection Data 5 3 Typical J1939 Wiring Topology 6 4 VeeCAN 128 Installation 7 5 Maintenance and Troubleshooting 9 6 Home Screen 10 7 Alarms Screen 12 Section Page 3 8 Main Menu 13 9 Glossary 14 10 Important Safety Information 15 ...

Page 4: ...ailable on the latest generation of electronically controlled systems The display offers 4 soft keys 128 x 64 pixel display area and 4 warning lights to signify engine fault failure It offers a Deutsh connector interface and a Mini USB port Fully sealed to IP 66 front and IP 67 back with Deutsch connector and rubber USB port plug inserted ...

Page 5: ...eutsch DT04 6P connector on the rear of the display wired as shown see pin out diagram 1 2 3 4 5 6 Ground and power 10 32VDC Supply should be protected by 500mA rated circuit breaker fuse Primary CAN Data High Primary CAN Data Low Low Side Relay Switch to Ground Analog Input ...

Page 6: ...t it is critical to use twisted shielded pair with a drain wire max length 40m terminated with 120 ohm resistors at each end In addition all stubs should not exceed 1m in length and a maximum of 30 nodes Engine and or Transmission Backbone Max length 40m Termination Resistor 120 ohm VeeCAN 128 Display Stub Max length 1m Termination Resistor 120 ohm Node 30 max ...

Page 7: ...cable connection to ensure that the cables are not unduly stressed and for ventilation Leave sufficient cable so that the unit may be removed for servicing Cut a 2 inch 51 mm hole Screw the studs into the rear case Place the VeeCAN 128 in position use the mounting bracket and thumb nuts to secure the units The thumb nuts should only be hand tight Connect the Deutsch mating part into the housing WA...

Page 8: ...8 Unit mounting method ...

Page 9: ... operating problems with VeeCAN 128 please refer to the following diagnostics Unit does not power up Unit fails to display any data Unit displays random data Ensure connections to unit are correct Ensure data source is broadcasting data Ensure source address in the display matches source data being provided by the engine and or transmission Ensure the J1939 backbone is connected and terminating re...

Page 10: ...ing Key 1 repeatedly will cycle through available quad screens 4 screen max Key 2 is a dual gauge view pressing Key 2 repeatedly will cycle through available dual screens 4 screen max Key 3 is a single gauge view pressing Key 3 repeatedly will cycle through available single screens 4 screen max NOTE Number of available screens can be adjusted to 2 3 or 4 screens for each option ...

Page 11: ...n Dual Screen SingleScreen Key highlights the data to be changed Key selects previous parameter Key selects next parameter Key exits adjust screen auto timeout aprox 30 sec All available screens can be adjusted in this manner Note Bar graph is only available on the dual and single screens both the minimum and maximum values can be adjusted Once in the desired gauge view quad dual single press and ...

Page 12: ...connected To acknowledge the alarm press Key 4 to acess alarm screen and then Key 3 to silence the alarm Pressing Key 4 again will exit alarm screen The alarm icons and LEDs will continue to flash until the alarm condition is resolved and alarm clear command is received from the engine and or transmission Check Engine Alarm will sound along with Orange LEDs Stop Engine Alarm will sound along with ...

Page 13: ...een the user can change Tier 4 modes NOTE Please refer to engine manual for further information regarding actions required for Tier 4 engines Settings Language and Key Tone options can be found here Protected Settings To access Protected Settings use PIN 1234 In the Protected Settings the user can change the units access Demo Mode J1939 settings Service Hours IO Setup Restore Defaults select Max Q...

Page 14: ...128 VEM Controller Area Network also referred to as CAN bus serial communication protocol for automotive use Veethree Engine Monitor J1939 SAE engine data protocol using CAN 2 0B LCD Liquid Crystal Display Soft keys Push button keys whose function changes according to use ...

Page 15: ...en used as a monitor for electronically controlled engines transmissions or other systems Veethree operates a policy of continuous improvement Veethree reserves the right to alter and improve the VeeCAN 128 displays and software without prior notice CE EMC Directive 2004 108 EC This product has been designed to be compliant with this directive Compliance can only be ensured by correct installation...

Page 16: ...VeeCAN 128 VEETHREE ENGINE MONITOR 70617 Rev 1 Veethree Electronics and Marine LLC 2050 47th Terrace East Bradenton Florida 34203 USA www v3instruments com 1 941 538 7775 Fax 1 941 755 1222 ...