background image

12

The order codes for the Veeder-Root 454501 Single Preset Counter are shown below:

Single Preset Counter (USA)

V45450-1

Single Preset Counter (UK/Europe)

V45450E1

Single Preset Counter (USA) - Low Voltage AC/DC supply

V45450-12

Single Preset Counter (UK/Europe) - Low Voltage AC/DC supply

V45450E12

In the UK:

Veeder-Root Division

West Instruments Limited
The Hyde
Brighton
E. Sussex BN2 4JU

Tel. +44 (0) 1273 606271
Fax: +44 (0) 1273 609990

In France:

Veeder-Root SARL

8 Place de la Loire
94583 Rungis Cedex

Tel. 33-146870981
Fax: 33-146868004

In Germany:

Veeder-Root GmbH

Morikestrasse 30
73761 Neuhausen ADF

Tel. 49-71589003-0
Fax: 49-71589003-32

In Brazil:

Veeder-Root do
Brasil

Rua Ado Benatti No-92
Caixa Postal, 8343
CEP 05037-010
São Paulo

Tel. 55-118612155
Fax: 55-118611982

1675 N. Delany Road
Gurnee, IL
60031-1282

Tel. 708.662.2666

This instrument is warranted to be free from defects in workmanship and material for a period

of three years from the date of despatch. In the unlikely event of a fault, call the appropriate

number below for a Return Material Authorisation (RMA) number.
The obligation of the Company under this warranty is limited to the repair or replacement of

this instrument. Should the cause of the fault be due to misuse or abuse of the instrument or the 

warranty period has expired, the customer shall be informed before any repair work is started.

Summary of Contents for V454501

Page 1: ...e V454500 family of preset counters combines state of the art circuitry and electronic assembly techniques with an ergonomic package design that results in the most cost effective high performance cou...

Page 2: ...s display of Count and Preset data Red LED display Annunciators show input display and output status Ergonomic Keypad Simple key sequences to view and edit Presets Front Panel Reset key can be disable...

Page 3: ...Current Sinking NPN Count Inputs Connect Add count input to Terminal 2 A and or Subtract count input to Terminal 3 B see below In Configuration Mode set PuLL parameter to YES and for Add Subtract oper...

Page 4: ...rom the front of the mounting panel and hold the Counter lightly in position against the panel Ensure that the panel gasket is not distorted and that the Controller is positioned squarely against the...

Page 5: ...ting left most digit will start to flash and to move between the digits Once the proper digit is selected flashing with the Next key its value can be altered through use of the Down key Program Mode U...

Page 6: ...ts are as required press the ENT key to confirm the changes the display will stop flashing IMPORTANT You must press the ENT key within 15 seconds of the last keypress when entering a new value otherwi...

Page 7: ...e digits will flash use Next key to select each digit to be adjusted and adjust digit value using Down key When adjustment is complete press ENT key to exit Edit Mode digits will become static 2 To ad...

Page 8: ...a parameter use the Down key to step through the parameters when the desired parameter description is shown in the upper display press the Next key to enter Edit Mode and to scroll through the availab...

Page 9: ...medium speed 25 0ms low speed Control Inputs Remote Reset Terminal 5 edge sensitive Program Mode Terminal 6 level sensitive Input Voltage High 3 0V or open Low 2 0V Input Impedance 4 7k to V Input Re...

Page 10: ...10 N O T E S...

Page 11: ...11 N O T E S...

Page 12: ...Neuhausen ADF Tel 49 71589003 0 Fax 49 71589003 32 In Brazil Veeder Root do Brasil Rua Ado Benatti No 92 Caixa Postal 8343 CEP 05037 010 S o Paulo Tel 55 118612155 Fax 55 118611982 1675 N Delany Road...

Reviews: