background image

Installation of Upgrade Kit

Safety Precautions

8

Figure 6.   Attaching the new door to the TLS2P console

983-7.eps

1

1

2

1

Get the two T-15 torx 

s

houlder 

s

crew

s

 and the new 

TLS2P door.

2

Position the door over the left holes in the top and 
bottom of the console and screw in the two shoulder 
screws (item 1 

in Figure 6

).

3

Loosen the grounding clamp (item 2 

in Figure 6

) in the 

door and push the grounding strap from the console 
under the saddle clamp and tighten the screw.

Summary of Contents for TLS2

Page 1: ...Manual No 577013 983 Revision B Upgrade Guide TLS2 to TLS2P...

Page 2: ...r Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax...

Page 3: ...kit 3 Procedure 3 Figures Figure 1 Removing TLS2 Console Door 3 Figure 2 Disconnecting the display assembly from the CPU board 4 Figure 3 Removing the display 5 Figure 4 Attaching the new CPU board in...

Page 4: ...por polisher installation wireless equipment installation tank and line preparation and line leak detector installation TLS 350 Technician Level 2 3 or 4 Certification Contractors holding valid TLS 35...

Page 5: ...id damage to equipment property envi ronment or personal injury STATIC SENSITIVE COMPO NENTS Wear grounded anti static wrist strap before handling the printed circuit board READ ALL RELATED MANUALS Kn...

Page 6: ...rs to fit T 10 and T 15 screws PROCEDURE Figure 1 Removing TLS2 Console Door 983 1 eps 2 3 1 1 2 Shut off tag and lockout power to the TLS2 Console 1 Remove and retain the top and bottom T 15 shoulder...

Page 7: ...1 Remove and retain the four T 10 screws spacers and washers items1 and 2 in Figure 2 attaching the display to the CPU board Retain the two shorter screws 0 5 long item 2 in Figure 2 and all of the wa...

Page 8: ...d wire saddle clamp on the inner door item 3 in Figure 3 3 Remove the ribbon cable from its connector on the edge of the CPU board item 4 in Figure 3 Notice the orientation of the ribbon cable in the...

Page 9: ...from its packing and push the ground cable and ribbon cable through the right side opening in the inner door assembly and place the inner door assembly on the console and screw in the two right side...

Page 10: ...rd items 1 and 2 in Figure 2 2 Get the display and attach its 2 wire cable plug to the connector on the CPU board item 1 in Figure 5 3 Push the display s ribbon cable into its connector on the CPU boa...

Page 11: ...T 15 torx shoulder screws and the new TLS2P door 2 Position the door over the left holes in the top and bottom of the console and screw in the two shoulder screws item 1 in Figure 6 3 Loosen the groun...

Page 12: ...ic preventing grounding strap from the inner door Remove the two right T 15 torx screws holding on the inner door item 1 Figure 6 close the new outer door reinsert the two shoulder screws in the two h...

Page 13: ...For technical support sales or other assistance please visit www veeder com...