TLS-IB Site Prep Manual
Signal Input Specifications
41
Signal Input Specifications
• Up to 8 Veeder-Root Magnetostrictive probes can be monitored.
• Probe data: 0.2 A at 13 volts.
TLS-IB IFSF Commands
The IFSF commands recognized by the TLS-IB are divided into 5 databases; Tank Level Gauge Database (Table 10),
Tank Level Gauge Error Code Database (Table 11), Tank Probe Database (Table 12), Tank Temperature Table Database
(Table 13), and Tank Probe Error Code Database (Table 14).
A11
Probe Fast Average Buffers
A12
Probe Standard Average Buffers
Table 10. Tank Level Gauge Database
Data Identification
Data Element Name
1
Nb_Tanks
3
TLG_Measurement_Units
6
Country_Code
7
Maint_Password
50
TLG_Manufacturer_Id
51
TLG_Model
52
TLG_Type
53
TLG_Serial_Nb
54
TLG_Appl_Software_Ver
58
IFSF_Protocol_Ver
61
SW_Checksum
70
Enter_Maint_Mode
71
Exit_Maint_Mode
255
V-R protocol pass through
Table 11. Tank Level Gauge Error Code Database
Data Identification
Data Element Name
1
TLG_Error_Type
3
TLG_Error_Total
Table 9. TLS-IB Serial Commands
Command
Description