RS-232 Commands
Function Code: A01
53
Function Code: A01
Function Type:
Probe Type and Serial Number
Version 1
Command Format:
Display:
<SOH>IA01TT
Computer:
<SOH>iA01TT
Typical Response Message, Display Format:
<SOH>
IA01TT
TT PP KKKK LLLL.LL SSSSSS cccc
<ETX>
Notes:
1.
TT
- Tank Number (Decimal, 00 = all)
2.
PP
- Probe Type: - MAG1
3.
LLLL.LL
- Probe Length (Decimal)
4.
SSSSSS
- Probe Serial Number (Decimal)
5.
cccc
- Probe Date Code (Hex)
Typical Response Message, Computer Format:
<SOH>iA01TT0000000000TT0PPKKKKFFFFFFFFSSSSSScccc...
TT0PPKKKKFFFFFFFFSSSSSScccc&&CCCC<ETX>
Notes:
1.
0000000000
- Not Used.
2.
TT
- Tank Number (Decimal, 00 = all)
3.
0
- Not used
4.
PP
- Probe Type: 03 = MAG1
5.
KKKK
- Circuit Code (Hex)
6.
FFFFFFFF
- Probe Length (ASCII Hex IEEE float)
7.
SSSSSS
- Probe Serial Number (Decimal)
8.
cccc
- Probe Date Code (Hex)
9.
&&
- Data Termination Flag
10.
CCCC
- Message Checksum