4
Troubleshooting Guide
HydrX Waste Water Tank - Draining Instructions
Dispose of waste water according to local guidelines.
Drain cycle is not executable via the web interface. Drain cycle must be executed via the GUI.
DRAIN WASTE WATER - FCC CONTROLLED HydrX
1. At the Fuel Conditioning Controller Home screen (see Figure 6), touch the
Service
button to open the FCC Service Home
screen (see Figure 7.
Figure 6. FCC Home Screen
Figure 7. FCC Service Screen
2. Touch
the
Auto Drain
button.
3. Place the nozzle into the approved waste water container and open the nozzle to fill the five gallon tank.
4. After filling the container, or until the draining automatically stops (the float is on the bottom of the HydrX tank), release the
nozzle and close the STP Adapter ball valve.
If drain cycle completes and the water float is reading above 0 the drain cycle may be repeated. If after
running an additional drain cycle the water float is still reading above 0, clean solid debris from the
bottom of the HydrX waste water tank (accessed through the Outlet Filter housing).
Tag, lockout power to the STP
.
5. Disconnect the drain hose from the HydrX Drain port and replace the cap on the drain fitting.
6. Turn on power to the STP.
7. Re-open the STP Adapter ball valve.
©Veeder-Root 2023 All rights reserved
.