Setup Mode
Setup Mode Categories
28
IB Address Setup
Figure 26 illustrates the IB Address setup selections (the default IB address is 1). This setup is necessary only
when there are more than one IBs connected in a network.
Figure 26. IB Address Setup
Head Address
Figure 27 illustrates Head Address setup choices (note Caution in figure below).
Figure 27. Head Address Setup
Initial Remote Display Setup
Connect both display heads to the IB box and apply power. In display head 2, enter
Setup Mode>System Address
and set
the Head Address to 2. Wait 10 seconds for communication to be established. After 10 seconds, configure the IB address
using either display head.
Put the Remote Display into the C&C Mode and enable it as a Remote Display (see Figure 45 on page 47). Press the NEXT
button to select which Display Head will be the master, such as LOCAL EMR HEAD 1. Press ENTER until CONFIGURE I/O is
displayed.
Exit the C&C Mode and return both Display Heads to the Volume Mode. Cycle power Off and On to the IB and verify Remote
Display operation by simulating a delivery.
When using two Display Heads each with its own meter (i.e. not using Remote Display), and one Display Head is programmed
to use multipoint calibration, the software does not require the other Display Head to use multipoint calibration; however, local
W&M regulations may require it. See Figure 45 on page 47 for information on enabling Remote Display.
Press ENTER to return
to SYSTEM ADDRESS
IB ADDRESS*
SET IB ADDRESS 1
SET IB ADDRESS 16
-
+
Press ENTER to accept
choice and return to
HEAD ADDRESS.
Press ENTER to return
to SYSTEM ADDRESS
HEAD ADDRESS
SET HEAD ADDRS 1*
SET HEAD ADDRS 2
-
+
*The default setting is 1.
CAUTION! For a 2 Display Head
system the Head Addresses must
be unique (i.e., 1 and 2).
CAUTION! If communication
problems occur or power is lost
while changing the head address,
cycle power to the IB box. Failure to
do so may result in either an IB
comm failure or a reset problem.