background image

VECTOR 

FOG.,1> 

PRODUCT GUARANTEE 

This product is guaranteed for twelve months from the date of original purchase. Any defect that arises 

due to faulty materials or workmanship will either be replaced or repaired during this period by the 

seller or authorised distributor from whom you purchased the unit. Transportation charges or duties 

shall be borne by Purchaser. 

The guarantee is subject to the following provisions: 

• The guarantee does not cover normal wear, accidental damage, misuse, damage or used for a 

purpose for which is not designed; altered in any way; or subjected to any but the specified voltage if 

applicable.

The product must be operated only by trained and skilled personnel and it must be correctly handled 

and operated in accordance with the instructions contained in this manual. The functional safety of the 

unit (e.g. by trial fogging with water) must be checked before putting the unit in operation. Any loose or 

leaking valves or lines should be repaired and fixed. If functional safety is not ensured, do not put the 

unit into operation. 

The guarantee will be rendered invalided if the product is re-sold, fitted with non-original spare parts or 

damaged by inexpert repair.

Chemical solutions must be officially approved for the intended application and the material safety 

data sheet of the chemical solution should be revised prior to operation. Oxygen and chlorine releasing 

chemicals (e.g. peroxides) and other acids should only be used with approved acid resistant equipment 

models. If not approved for acid resistance a Ph-value should be limited from 4,5-8,5. After use, fog with 

some clean water for about 3 minutes to remove any chemicals still left in the system. Ensure all the 

water is used up and the machine is dried prior to storage. Damage caused by corrosion due to 

humidity by wrongful storage will invalidate this guarantee.

Any formation of aerosols or fogs from flammable substances or acids releasing oxygen and 

a mixture with air and/or dust always involves the risk of fire or explosion if there is a source of ignition. 

Observe the explosion limit of a pesticide and avoid over dosage accordingly. Only use

non-inflammable liquids (without a flash point) for treatments in rooms where a dust explosion hazard 

exists. Unit is not explosion proof.

• Operators owe a duty of care to prevent unreasonable 

risk 

of harm or 

injury. 

Operators should not 

fog towards hot surfaces or electric cables nor fog in rooms with a temperature  exceeding 35

°

C.  Only 

treat closed rooms. Position the unit in a safe and upright position with the hand piece hooked or carry it 

with the strap over your shoulder. In case of stationary use, do not leave the unit unattended. Secure 

treated rooms against unauthorized access (i.e. provide warnings outside). Always keep treated rooms 

closed and eliminate leakages. Ventilate treated rooms sufficiently before re-using them. 

Specifications are subject to change without notice. The manufacturer disclaims any liability for the 

incidental or consequential damages. The guarantee is in addition to, and does not diminish your 

statutory or legal rights.  In the event of a problem with the product within the guarantee period call the 

Customer Helpline on +44 20 3808 5797

Summary of Contents for VECTOR FOG C100 Plus

Page 1: ...VECTOR FOG USER MANUAL ULV FOGGER C20 C100 Plus C150 Plus 2020 Vectorfog is a trademark of Vectornate Ltd...

Page 2: ...ace the fuse please use a 15 amp fuse with the correct voltage Failure to use the right fuse could cause an electrical fault or motor to overheat The fuse is located above the power cords female coupl...

Page 3: ...02 PRODUCT OVERVIEW for 10 minutes...

Page 4: ...ular or viscous in nature doing so will damage the machine and void the warranty Pre mix the chemicals prior to filling the tank Mix the chemicals according to manufacturer s instructions Do not overf...

Page 5: ......

Page 6: ...get rid of any existing liquid remaining in the fogger s internal tubes STEP B Fill the fogger with some clean water and operate again for one minute Remove any excess water from the tank Cleanup of...

Page 7: ...1 2...

Page 8: ...7 P C B S w i t c h A s s y 7 1 P C B 1 8 P o w e r C a b l e 7 2 S w i t c h A s s y...

Page 9: ...4 8 0 x 2 0 0 x 2 5 0 mm 2 L 5 2 5 x 1 6 5 x 3 0 5 mm 6 3 0 x 1 9 5 x 3 1 0 mm...

Page 10: ...approved for acid resistance a Ph value should be limited from 4 5 8 5 After use fog with some clean water for about 3 minutes to remove any chemicals still left in the system Ensure all the water is...

Page 11: ...e is not for fogging any powder based solutions these can cause blockages and damage to the machine Only use solutions between the pH levels of 3 and 10 3 Please do not lay the machine on the left sid...

Page 12: ...T E L U K 4 42 03 8 0 85 7 9 7 K O R E A 8 2 0 7 04 6 9 42 4 8 9 U S 12 0 14 8 29 8 3 5 E ma i l i n f o v e c t o r f o g c o m...

Reviews: