background image

 

TRI2-FU 

P

RODUCT 

D

ATA 

S

HEET

 

 

Doc: 70-00-0750C, 20230220 

© Vector Controls GmbH, Switzerland 

Page 6-10 

Subjects to alteration 

www.vectorcontrols.com 

V

ECTOR

 

Operation and Configuration 

 

Documentation 

This controller uses the latest generation X2 operating system. Detailed operation instructions for all devices equipped 

with this operating system can be found on our website. 
Also available are programming instructions for technicians and an application database. 

 

 

Configuration 

 

The device can be fully configured and commissioned using the EasySet program or the built-in 

operation terminal. 

EasySet may be downloaded free of charge from our website

 

www.vectorcontrols.com

.

 

 

Configuring the TRI2 device 

 

Configuring with EasySet 

(free PC application)

 

Use the PC and the EasySet tool to easily configure the TRI2 to your needs. Connect the PC with the 
EasySet tool ether with the AEC-USB converter and the AEC-TRI-2 configuration adapter to the TRI2 or 

use the Wi-Fi communication of the PC to connect to the TRI2 (for TRI2-WIM /-WIB devices only). See 

TRI2 installation sheet for connection details. 

 

 

Configuring with Operation Terminal 

You can use the built-

in operation terminal to configure the TRI2 to your needs. See “X2 Operations Manual touch display” 

and “X2 Engineering Manual” for details.

 

 

Copy Configuration to other TRI2 devices 

Complete parameter sets may be copied using the accessory AEC-PM2 or exchanged with a PC 

using the EasySet tool and an RS485-USB converter or via Wi-Fi communication. 

 

 

Copy configuration with the AEC-PM2 

Use the configuration adaptor ACE-TRI-2 to load the configuration onto the AEC-PM2 plug-in 

memory (see TRI2 installation sheet for connection details). 
To copy the configuration to other TRI2 devices, connect the AEC-PM2 plug-in memory to the 

TRI2 and simply press the copy button (see TRI2 installation sheet for connection details). 

 

 

Copy configuration with EasySet 

(free PC application)

 

To copy the configuration to other TRI2 devices, connect the PC with the EasySet tool ether with the AEC-USB converter 

and the AEC-TRI-2 configuration adapter to the TRI2 or use the Wi-Fi communication of the PC to connect to the TRI2 (for 
TRI2-WIM /-WIB devices only). See TRI2 installation sheet for connection details. 

 

Documentation overview 

 

Document Type 

Document No. 

Description 

TRI2-FU Data Sheet 

70-00-0750 

Product data sheet (this document) 

TRI2-FU Install Sheet 

70-00-0743 

Mounting and installation manual 

X2 Operations Manual touch display  

70-00-0951 

Operations instructions of X2 system with touch display 

X2 Web Interface operation manual 

70-00-0952 

Operations instructions of X2 Web interface 

X2 Engineering Manual 

70-00-0737 

Guidelines for configuring the X2 system 

X2 Modbus Communication Module 

(-MOD type) 

70-00-0290 

Setup and configuration manual Modbus (no Modbus TCP) 

X2 Modbus Communication Module 

(-WEM type) 

70-00-0925 

Setup and configuration manual Modbus TCP 

X2 BACnet Communication Module 

(-BAC type) 

70-00-0218 

Setup and configuration manual BACnet (no BACnet/IP) 

X2 BACnet/IP Communication Module 

(-WEB type) 

70-00-0899 

Setup and configuration manual BACnet/IP 

X2 Wi-Fi / Ethernet Communication 

Manual 

(-WEM, -WEB type) 

70-00-0900 

Setup and configuration manual TCP/IP 

 

Note: The above list is not complete. The documents on the website are relevant. 

 

 

 

AEC-PM2 

AEC-TRI-2 

AEC-USB 

Summary of Contents for TRI2 Series

Page 1: ...y and dew point calculations o Transmitter function for inputs and set points Built in humidity and temperature sensors 2 passive inputs NTC open contact 1 analog input VDC and 2 analog outputs VDC 2...

Page 2: ...l inputs Passive input Type Range UI4 to UI5 Passive Temperature NTC or open contact NTC Sxx Tn10 10k 25 C 40 100 C 40 212 F Analog input Type range Resolution UI6 in Voltage mode 0 10 VDC 9 76 mV 10...

Page 3: ...odd parity 1 stop BACnet BAC Communication standard BACnet MS TP over RS485 BTL tested and listed B ASC Communication speed 9600 19200 38400 57600 76800 115200 Technical specification for TCP IP comm...

Page 4: ...TRI2 FU PRODUCT DATA SHEET Doc 70 00 0750C 20230220 Vector Controls GmbH Switzerland Page 4 10 Subjects to alteration www vectorcontrols com VECTOR Dimension mm inch...

Page 5: ...Tn10 20 AMI S10 as immersion sensor Actuators Choose modulating actuators with an input signal type of 0 2 10 VDC 3 point actuators with constant running time are recommended Binary auxiliary devices...

Page 6: ...ion adaptor ACE TRI 2 to load the configuration onto the AEC PM2 plug in memory see TRI2 installation sheet for connection details To copy the configuration to other TRI2 devices connect the AEC PM2 p...

Page 7: ...synchronisation B DM RD B Device management Reinitialize device B Supported standard BACnet application services ReadProperty ReadPropertyMultiple WriteProperty DeviceCommunication password protected...

Page 8: ...al functions AL 1AL to 8AL 8 Alarm conditions LP 1L to 2L 2 Control loops AO 1A to 2A 2 Analog outputs for mA VDC FAN 1F 1 Fan or lead lag modules 1 to 3 fan speeds up to 3 switching lead lag stages e...

Page 9: ...TRI2 FU PRODUCT DATA SHEET Doc 70 00 0750C 20230220 Vector Controls GmbH Switzerland Page 9 10 Subjects to alteration www vectorcontrols com VECTOR Empty page...

Page 10: ...220 Vector Controls GmbH Switzerland Page 10 10 Subjects to alteration www vectorcontrols com VECTOR Smart Sensors and Controls Made Easy Quality Innovation Partnership Vector Controls GmbH Switzerlan...