AVERAGE NUMBER OF USES

    POTENTIAL TOTAL NUMBER

(JUMPSTART OR DISCHARGES)

OF JUMPSTART OR DISCHARGE CYCLES

 BETWEEN RECHARGES

    (LIFETIME OF UNIT BATTERY

               1

                 1000+

               5

                  700+

              10

                 

500+

3. Insert the plug at the other end of this power cord into the 12-volt DC receptacle on the front panel of the unit.
4. Charge the unit until the green FULL indicator lights when Charge Status Indicator Button is pressed.

DO NOT EXCEED 3-4 HOURS MAXIMUM.

5. When charging is completed, remove the power cord and store in a safe place.

3.3

110/120 VAC Charging Using VECO7O 1.5 Amp Automatic Battery Charger

(purchased separately)

1. Install the charger

*

s DC wire with battery clips.

2. The jumpstarter has a high-current switch for turning the heavy-duty clamps ON and OFF. Make sure the Safety switch is turned       
OFF.

3. Connect the POSITIVE (RED) DC Battery Clip to the RED POSITIVE jumpstarter clomp.

4. Connect the NEGATIVE (BLACK) DC Battery Clip to the BLACK NEGATIVE jumpstarter clamp.

5. Connect the charger to an AC outlet or extension cord rated at 18 AWG or larger.

6. Turn ON the Safety switch and observe the RED LED on the charger for proper operation.

7. Charge the START-IT

until the green Charged LED lights when FULL Status Button is pressed. Then continue charging for

TM 

another hour.

B. When charging is complete, Turn OFF the Safety switch.

9. Disconnect the charger from the AC outlet or extension cord.

10. Disconnect the charger

*

s battery clips from the jumpstarter

*

s clamps.

11. Store the charger as described in it

*

s Owner

*

s Manual.

12. Place the jumpstarter back into service.

3.4

Estimated Battery Life

Table I shows the relationship of the frequency of use between recharging and the expected number of
discharge/recharge cycles

Table I 

— 

Estimated Battery Life

Summary of Contents for Start-IT VECO21 ST

Page 1: ......

Page 2: ...lt DC Charging 8 3 3 110 120 Volt AC Charging Using VECO7O Automatic 1 5 Amp Battery Charger 9 3 4 Estimated Battery Life 9 4 OPERATING AS A PORTABLE POWER SUPPLY 4 1 Operating as a 12 Vail DC Power Supply 9 4 2 Estimated 12 Volt DC Usage Times 10 4 3 Operation as a 110 120 Volt AC Power Supply 10 5 EMERGENCY WORK LIGHT 10 6 BATTERY REPLACEMENT 6 1 Battery Disposal 11 7 SPECIFICATIONS 11 WARRANTY ...

Page 3: ... THE UNIT ON A FLAT STABLE SURFACE BE SURE TO KEEP ALL CLAMPS CORDS CLOTHING AND BODY PARTS AWAY FROM MOVING VEHICLE COMPONENTS 9 DO NOT WEAR VINYL CLOTHING WHEN JUMPSTARTING A VEHICLE FRICTION CAN CAUSE DANGEROUS STATIC ELECTRICITY SPARKS REMOVE ALL JEWELRY OR METAL OBJECTS THAT COULD CAUSE SHORT CIRCUITS OR REACT WITH BATTERY ACID 10 ALWAYS DISCONNECT THE NEGATIVE BLACK JUMPER CABLE FIRST FOLLOW...

Page 4: ...Y DO NOT ATTEMPT TO JUMPSTART A VEHICLE THAT DOES NOT HAVE A BATTERY INSTALLED 9 VEHICLES THAT HAVE ON BOARD COMPUTERIZED SYSTEMS MAY BE DAMAGED IF VEHICLE BATTERY IS JUMPSTARTED BEFORE JUMPSTARTING READ THE VEHICLE S OWNER S MANUAL TO CONFIRM THAT EXTERNAL STARTING ASSISTANCE IS ADVISED 10 EXCESSIVE ENGINE CRANKING CAN DAMAGE A VEHICLE S STARTER MOTOR IF THE ENGINE FAILS TO START AFTER THE RECOMM...

Page 5: ...key required no key to get lost Built in audible reverse polarity alarm Cordless rechargeable includes charging cords for standard 110 120 volt AC wall socket and vehicle s 12 volt DC accessory outlet Powerful 400 instantaneous cranking amps 1 200 peak amps Solid state automatic operation and built in circuit protection Safe to use transport and store Includes non spillable maintenance free heavy ...

Page 6: ...DDITIONAL HOUR USING THE DC METHOD OR 2 4 HOURS USING THE AC METHOD 3 FULLY RECHARGE UNIT AFTER EACH USE OR WHEN CHARGE STATUS INDICATOR SHOWS LOWER THAN 4 RED LED AND EVERY 2 MONTHS WHEN NOT IN USE 4 ALWAYS RECHARGE IN A DRY WELL VENTILATED AREA AWAY FROM WATER 5 WHEN CHARGING IN ANY WET OR DAMP AREA FROM A 110 120 VOLT ELECTRICAL OUTLET MAKE SURE THAT THE OUTLET USED IS PROTECTED BY A GROUND FAU...

Page 7: ...ette lighter This allows maximum portability and utility when the START IT is used in remote locations TM For maximum convenience the START IT can be recharged from any standard 110 120 volt AC or 12 volt DC power source using TM the built in 12 volt socket and the appropriate charging adapter cord When pressed the CHARGE STATUS button will show the battery s power level status from Low to Full Th...

Page 8: ...move or secure any loose clothing items and restrain long hair before attempting jumpstart procedure WARNINGS 1 Vehicles that have on board computerized systems may be damaged if vehicle battery is jumpstarted Before jumpstarting this type of vehicle read the vehicle owner s manual to confirm that external starting assistance is advised 2 Excessive engine cranking can damage the vehicle s starter ...

Page 9: ...e clamps disconnect the negative Black jumper cable first followed by the positive Red jumper cable and replace them in the built in storage holsters CAUTIONS 1 If vehicle fails to start leave vehicle ignition key turned OFF disconnect the negative clamp first then the positive clamp and discontinue jumpstarting procedure 2 Recharge jumpstart system after each use WARNINGS 1 ALWAYS disconnect the ...

Page 10: ...lt DC receptacle on the unit 3 Charge this device for at east 14 16 hours or until the FULL indicator lights when Charge Status Button is pressed 4 NOTE The unit can be overcharged which will shorten the life of the battery DO NOT charge with AC charging procedure for more than 24 hours maximum 5 When charging is completed remove the power cord and store in a safe place NOTE RECHARGE WHEN LESS THA...

Page 11: ...s turned OFF 3 Connect the POSITIVE RED DC Battery Clip to the RED POSITIVE jumpstarter clomp 4 Connect the NEGATIVE BLACK DC Battery Clip to the BLACK NEGATIVE jumpstarter clamp 5 Connect the charger to an AC outlet or extension cord rated at 18 AWG or larger 6 Turn ON the Safety switch and observe the RED LED on the charger for proper operation 7 Charge the START IT until the green Charged LED l...

Page 12: ...SE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN 20 AMPS 4 2 Estimated 12 Volt DC Usage Times Table II shows the estimated 12 volt DC operation times when using a fully charged system Table II START IT as a 12 Volt DC Power Supply TM NOTE ALL TIMES ARE APPROXIMATE AND BASED UPON FULLY CHARGED UNIT 4 3 Operation as a 110 Volt AC Power Supply Use with VECO4O 50 Watt VECO23 175 Watt or VECO24 4...

Page 13: ...IS UNIT CONTAINS A MAINTENANCE FREE SEALED NON SPILLABLE LEAD ACID BATTERY WHICH MUST BE DISPOSED OF PROPERLY SOME STATES REQUIRE RECYCLING DISPOSAL QUESTIONS IN USA CALL 1 877 288 7722 WARNINGS DO NOT DISPOSE OF THE BATTERY IN FIRE AS THIS MAY RESULT IN AN EXPLOSION BEFORE DISPOSING OF THE BATTERY PROTECT EXPOSED TERMINALS WITH HEAVY DUTY ELECTRICAL TAPE TO PREVENT SHORTING SHORTING CAN RESULT IN...

Page 14: ...flood and Acts of God If your problem is not covered by this warranty call our Technical Support Department at 954 584 4446 or toll free at 866 584 5505 for general repair information and charges if applicable You may also contact us through our website at www vectormfg com STATE LAW RIGHTS This warranty gives you specific legal rights Some states do not allow limitations on how long an implied wa...

Reviews: