1. INTRODUCTION

Congratulations

on selecting the Vector

®

START-IT™ JUMPSTART SYSTEM & 12-VOLT DC POWER SUPPLY

.

Please read this guide carefully before use to ensure optimum performance and avoid damage to the unit or items
that you are using it with. 

The Vector

®

START-IT™ JUMPSTART SYSTEM & 12-VOLT DC POWER SUPPLY

is a compact, durable and portable

jumpstart system for vehicles and boats that have a standard 12-Volt battery system. This self-contained, recharge-
able system will start most vehicles and boats without the need for a host vehicle or 110/120-volt AC power supply. 
It can also be used as a safe, portable source of 12-volt DC electric power in remote locations and/or emergency
situations. It is ideal for use with Vector

®

12-volt DC cordless, portable, rechargeable products and PowerForce

®

DC/AC Power Inverters. Use the 

START-IT™

to:

-

Jumpstart

Any vehicle with a standard 12-volt DC battery system: boat, truck, car, airplane, RV, personal watercraft, 
snowmobile, tractor, etc.
-

Operate: 12-volt DC 

Fans, inflators, fluorescent work lights, cellular phones*, air compressors, spotlights, TVs, portable 
radios, cassette or CD players and more. *Can quick-charge a cellular phone by using the phone’s 12-volt DC
adapter cord.
-

Operate: Certain 110/120-volt AC Accessories (requires DC to AC power inverter, sold separately) 

The 

START-IT™ SYSTEM 

has an easy-to-read, series of LED (Light Emitting Diode) charge indicators that show when the

unit is fully charged, or the level of charge in the battery. Charge level can be viewed when the charge status 
button is pressed. A 12-volt DC cigarette lighter-type socket is provided for use with appliances that can operate from
a vehicle cigarette lighter. This allows maximum portability and utility when the 

START-IT™ 

is used in remote locations. 

For maximum convenience, the 

START-IT™

can be recharged from any standard 110/120-volt AC or 12-volt DC

power source using the built-in 12-volt socket and the appropriate charging/adapter cord. When pressed, the
CHARGE STATUS button will show the battery‘s power level status (from Low to Full). The green LED full indicator 
illuminates when the unit is fully recharged and charging can be discontinued. An ON/OFF switch operates the 
built-in work/emergency light.

WARNING:

Lead-acid batteries generate hydrogen gas during normal operation. More gas is generated when the battery is
charging. Hydrogen gas is:  EXPLOSIVE  •  POISONOUS TO BREATHE  •  HIGHLY FLAMMABLE

To avoid an explosion and/or the possibility of being splashed with battery acid:
• NEVER allow the red and black clamps to touch each other or a common metal object. 
• ONLY attempt to jumpstart a vehicle or boat in a WELL ventilated area.
• ALWAYS CONNECT THE RED (+) CLAMP TO THE POSITIVE (+) BATTERY TERMINAL FIRST.
• DO NOT CONNECT THE BLACK (-) CLAMP TO THE NEGATIVE (-) BATTERY TERMINAL.
• DO CONNECT THE BLACK (-) CLAMP TO A NON-MOVING METAL PART ON THE ENGINE.

CAUTIONS:

I.  To avoid possible damage that may shorten the unit’s working life, protect this unit from direct sunlight, 

direct heat, and/or moisture.

2. This system is designed to be used ONLY on vehicles or boats with 12-volt DC battery systems.
3. This system is NOT designed to be used as a replacement for a vehicular battery.

RECOMMENDATIONS FOR OPTIMUM PERFORMANCE OF THE

START-IT™ JUMPSTART SYSTEM:

WARNING:

NEVER insert anything other than the supplied power/recharging cords or recommended 

appliance power/recharging cords into the charging/power sockets on this unit.

IMPORTANT: The safety ON/OFF switch should be in the OFF position when the unit is 
charging, or not in use.

5

Summary of Contents for START-IT VEC021ST

Page 1: ...S MANUAL INCLUDES INSTRUCTIONS FOR 110 VOLT AC POWER INVERTER OPTION THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USE READ AND...

Page 2: ...g 8 3 2 12 Volt DC Charging 8 3 3 110 120 Volt AC Charging Using VEC070 Automatic 1 5 Amp Battery Charger 9 3 4 Estimated Battery Life 9 4 OPERATING AS A PORTABLE POWER SUPPLY 4 1 Operating as a 12 Vo...

Page 3: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents...

Page 4: ......

Page 5: ...UNIT ON A FLAT STABLE SURFACE BE SURE TO KEEP ALL CLAMPS CORDS CLOTHING AND BODY PARTS AWAY FROM MOVING VEHICLE COMPONENTS 9 DO NOT WEAR VINYL CLOTHING WHEN JUMPSTARTING A VEHICLE FRICTION CAN CAUSE...

Page 6: ...NOT ATTEMPT TO JUMPSTART A VEHICLE THAT DOES NOT HAVE A BATTERY INSTALLED 9 VEHICLES THAT HAVE ON BOARD COMPUTERIZED SYSTEMS MAY BE DAMAGED IF VEHICLE BATTERY IS JUMPSTARTED BEFORE JUMPSTARTING READ...

Page 7: ...ycling contact your local authority for information THIS UNIT CONTAINS A MAINTENANCE FREE SEALED NON SPILLABLE LEAD ACID BATTERY WHICH MUST BE DISPOSED OF PROPERLY SOME STATES REQUIRE RECYCLING DISPOS...

Page 8: ...C Power Supply NOTE ALL TIMES ARE APPROXIMATE AND BASED UPON FULLY CHARGED UNIT 4 3 Operation as a 110 Volt AC Power Supply Use with VEC040 50 Watt VEC023 175 Watt or VEC024 400 Watt Maxx Power Invert...

Page 9: ...ng amps 1200 peak amps Solid state automatic operation and built in circuit protection Safe to use transport and store Includes non spillable maintenance free heavy duty 19 amp hour sealed battery Req...

Page 10: ...AN ADDITIONAL HOUR USING THE DC METHOD OR 2 4 HOURS USING THE AC METHOD 3 FULLY RECHARGE UNIT AFTER EACH USE OR WHEN CHARGE STATUS INDICATOR SHOWS LOWER THAN 4 RED LED AND EVERY 2 MONTHS WHEN NOT IN...

Page 11: ...he NEGATIVE BLACK DC Battery Clip to the BLACK NEGATIVE jumpstarter clamp 5 Connect the charger to an AC outlet or extension cord rated at 18 AWG or larger 6 Turn ON the Safety switch and observe the...

Page 12: ...tlet 2 Plug the 12 volt DC cigarette type plug into the 12 volt DC receptacle on the unit 3 Charge this device for at least 14 16 hours or until the FULL indicator lights when Charge Status Button is...

Page 13: ...e lighter This allows maximum portability and utility when the START IT is used in remote locations For maximum convenience the START IT can be recharged from any standard 110 120 volt AC or 12 volt D...

Page 14: ...strain long hair before attempting jumpstart procedure WARNINGS 1 Vehicles that have on board computerized systems may be damaged if vehicle battery is jumpstarted Before jumpstarting this type of veh...

Page 15: ...ve clamps disconnect the negative Black jumper cable first followed by the positive Red jumper cable and replace them in the built in storage holsters CAUTIONS 1 If vehicle fails to start leave vehicl...

Page 16: ...VECTOR MANUFACTURING Ltd 4140 S W 28th Way Ft Lauderdale FL 33312...

Reviews: