background image

10

wattage rating.  Induction motors, as well as some televisions, may

require 2 to 6 times their wattage rating to start up. The most demand-

ing in this category are those that start under load, such as compressors

and pumps. Testing is the only definitive way to determine whether a

specific load can be started and how long it can run. The unit will simply

shut down if it is overloaded.  To restart the unit after a shutdown due to

overloading, momentarily turn off the power to the unit.

CAUTION:

 This inverter will not operate high wattage appliances or

equipment that produce heat, such as hair dryers, microwave ovens,

and toasters.

4.2  BATTERY  OPERATING TIME

With a typical vehicle battery, a minimum operating time of 2 to 3 hours

can be expected. In most instances, 5 to 10 hours of operating time is

achievable. However, Vector recommends that the operator start the

vehicle every 2 to 3 hours to recharge the battery system. This will guard

against any unexpected shut-down of the equipment and will ensure

that there is always sufficient battery capacity to start the vehicle's

engine. The inverter will sound it's alarm when DC voltage drops to

10.6V.
The inverter may be used whether or not the vehicle's engine is running.

However, the inverter may not operate while the engine is starting since

the battery voltage can drop substantially during cranking.
The inverter draws less than 0.3 ampere from the battery when it is not

supplying power to a load. In most instances, the inverter can be left

connected to the battery when not in use since it draws so little current.

However, if the vehicle is to remain unused for several days, disconnect

the inverter from the battery.

5.

PROTECTIVE FEATURES OF THE INVERTER

Your Power-On-Board™ 400 monitors the following potentially hazard-

ous conditions:
Low Battery Voltage - This condition is not harmful to the inverter but

could damage the power source. An audible alarm will sound when

input voltage drops to 10.6. The Power-On-Board™ 400

automatically shuts down when input voltage drops to 10.0 volts. When

the condition is corrected, the unit may be restarted.

Summary of Contents for Power On Board VEC031POB

Page 1: ...RAGE OF THIS PRODUCT BEFORE USE READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE...

Page 2: ...g on appliances Multiple outlet power strips with switches and circuit breakers only interrupt power to the hot receptacle terminals The neutral terminals remain powered with respect to the ground ter...

Page 3: ...equirements 6 3 2 Connection to Power Source 6 8 3 3 Connection to Load 8 3 4 Fuse Replacement 8 3 5 Placement of the Inverter 9 4 OPERATING TIPS 9 10 4 1 Rated Versus Actual Current Draw of Equipment...

Page 4: ...efits our customers The new design more efficiently cools the power transistors and thereby increases reliability and the life of the product Given proper care and appropriate use your inverter is cov...

Page 5: ...olts which is the same as standard household power Most AC voltmeters both digital and analog are sensitive to the average value of the waveform rather than the RMS value They are calibrated for RMS v...

Page 6: ...Power On Board 400 comes equipped with a cigarette lighter plug and battery clip cables for connection to the power source CAUTION Do not use with positive ground electrical systems the majority of m...

Page 7: ...clips and terminals are secure Direct Hardwiring to Power Source Use 10 AWG wire if the inverter to power source connection is 10 feet or less For longer cable lengths use 8 AWG wire In either case p...

Page 8: ...ed above Do not connect the Power Inverter to household or RV AC distribution wiring Do not connect the Power Inverter to any AC load circuit in which the neutral conductor is connected to ground eart...

Page 9: ...periods of time The unit will shut down if the internal temperature exceeds 90 C The unit will restart after it cools SAFE Do not use the inverter near flammable materials or in any locations that may...

Page 10: ...unexpected shut down of the equipment and will ensure that there is always sufficient battery capacity to start the vehicle s engine The inverter will sound it s alarm when DC voltage drops to 10 6V T...

Page 11: ...ronic device at this time since the inverter will shut down automatically shortly there after when the battery voltage drops to 10 volts Start your engine to recharge the battery If the low voltage al...

Page 12: ...D ON TROUBLE INDICATION POSSIBLE CAUSE SUGGESTED REMEDY No AC output DC input below 10 Volts Recharge or replace red LED lit battery No AC output Excessive appliance Reduce load wait for red LED lit l...

Page 13: ...interference in speaker antenna distant from each other Use shielded antenna cable Connect antenna to amplifier 8 SPECIFICATIONS Maximum Continuous Power 400 watts Surge Capacity Peak Power 800 watts...

Page 14: ...stage prepaid to Vector Manufacturing Any defective product other than accessories that is returned to Vector Manufacturing within 30 days of the date of purchase will be replaced free of charge If su...

Page 15: ...keep the original packaging in case you need to ship the unit When returning a product include your name address phone number dated sales receipt or copy and a description of the reason for return and...

Page 16: ...16 2001 VECTOR MANUFACTURING LTD FT LAUDERDALE FL 33312 MADE IN CHINA...

Reviews: