OPA2-MOD(-H) 

Technical data

 

 

Doc: 70-00-0290, V1.0 R0, Date: 20160208 

© Vector Controls GmbH, Switzerland 

Page 2 

Subject to alteration 

Technical specifications 

Power Supply 

Power Requirements  

24 VAC ±10%, 50/60 Hz, 24VDC ±10% 

SELV to HD 384, Class II, 48VA max

 

 

Power Consumption 

Max. 1 VA 

 

Terminal Connectors 

For wire 0.34…2.5 mm2 (AWG 24…12)

 

Sensors 

Internal temperature sensor 

Range 

Accuracy 

NTC 

0…50 °C (32…122 °F) 

±0.5 K 

 

Humidity Sensor AES-HT-Ax: 

Range 

Measuring Accuracy 

Hysteresis 

Repeatability 

Stability 

Capacity sensor  

0…100 % RH  

See Figure to the right 

 1% 

 0.1% 

< 0.5% / year 

 

Signal inputs 

Temperature Input(RT) 

Range 

Accuracy 

For NTC sensors with 10kΩ bei 25°C(77°F) 

-40…140 °C (-40…284 °F) 

-40…0 °C (-40…32 °F): 0.5 K 
0…50 °C (32…122 °F): 0.2 K 
50…100 °C (122…212 °F): 0.5 K 
> 100 °C (> 212 °F): 1 K 

 

Digital Inputs 

Range 

DI1 and DI2 

Potential free, open = 1, closed = 0 

Network 

Hardware interface 

Max. nodes per network 

Max. nodes per segment 

RS485 in accordance with EIA/TIA 485 

128 

64 (Vector devices only) 

 

Conductors 

Impedance 

Nominal capacitance 

Shielded Twisted Pair (TSP) cable 

100 - 130 ohm  

100 pF/m 16pF/ft or lower 

 

Galvanic Isolation 

The communication circuitry is isolated 

 

Line termination 

A line termination resistance (120 ohm) shall be 

connected between the terminals (+) and (-) of the 

furthermost node of the network 

 

Network topology 

Daisy chain according EIA/TIA 485 specifications 

 

Recommended maximum length per chain 

1200 m (4000 ft) 

Environment 

Operation: 

Climatic Conditions 

Temperature 

Humidity 

Mechanical Conditions 

To IEC 721-3-3 

class 3 K5 

0…50 °C (32…122 °F) 

<95 % r.H. non-condensing 

class 2M2 

 

Transport & Storage: 

Climatic Conditions 

Temperature 

Humidity 

Mechanical Conditions 

To IEC 721-3-2 and IEC 721-3-1 

class 3 K3 and class 1 K3 

-25…70 °C (-13…158 °F) 

<95 % r.H. non-condensing 

class 2M2 

Standards EU 

 conformity 
EMC Directive 

Low Voltage Directive 

2004/108/EC 

2006/95/EC 

 

Product standards 

Automatic electrical controls for household 

and similar use 

 

EN 60 730 –1 

 

 

Electromagnetic compatibility for  

industrial and domestic sector 

Emissions: EN 60 730-1 

Immunity: EN 60 730-1 

 

Degree of Protection 

IP30 to EN 60 529 if mounted correctly 

 

Pollution Class 

II (EN 60 730-1) 

 

Safety Class: Local regulations must be 

observed! 

III (IEC 60536) 

 

Overvoltage Category 

II (EN 60 730-1) 

General 

Material 

Front part, back part 

 

Mounting plate 

Fire proof ABS plastic (UL94 class V-0) 

Galvanized steel 

 

Dimensions (H x W x D) 

Front part: 88 x 88 x 21 mm (3.5” x 3.5” x 0.8”)  

Back part: ø 58 x 32 mm (ø 2.3” x 1.3”) 

 

Weight (including package) 

240g (8.47 oz) 

 

 

Max RH tolerance at 25°C (77°F) 

 %rH 

%RH 

10 20 30 40 

10

90 

50 60 70 80 

±1 
±0 

±2 

±3 

±4 

±5 

AES-HT-A2 

AES-HT-A3 

AES-HT-A5 

Summary of Contents for OPA2-MOD

Page 1: ...led based on these inputs An external temperature may be measured through the additional temperature input This may be useful for underfloor heating sensor averaging for large rooms outdoor temperatur...

Page 2: ...ll be connected between the terminals and of the furthermost node of the network Network topology Daisy chain according EIA TIA 485 specifications Recommended maximum length per chain 1200 m 4000 ft E...

Page 3: ...above air discharge grills and diffusers Location of mounting is less critical if external temperature sensors are used Installation 1 Connect the wires to the terminals of the power case according to...

Page 4: ...uccessfully for the time period defined with CP18 1022 Verify wiring or operation of Modbus master device To disable this error set CP18 1022 to 0 Err2 The selected sensor is damaged or missing NA The...

Page 5: ...selection on right key 1 one zone 5 five zones 0 5 1 CP 06 Setpoint change enable 0 disabled 1 enabled 0 1 1 CP 07 Operation mode change ON OFF enabled 0 disabled 1 enabled 0 1 1 CP 08 Operation mode...

Page 6: ...M 1014 Bit R W AM PM flag 0 AM 1 PM 1015 Bit R W Celsius Fahrenheit 0 Celsius 1 Fahrenheit 1016 Byte R W Timeout in seconds to idle mode 0 255 seconds 1017 Bit R W Idle mode 0 disabled 1 enabled If en...

Page 7: ...umber of fan speeds 1 3 2003 8bit R W Actual fan speed 2004 bit R W Show fan symbol 0 2005 bit R W Show alarm symbol 0 2006 bit R W Show alarm string 0 2007 bit R W Show heating symbol 0 2008 bit R W...

Page 8: ...value zone 1 5001 3 setpoint zone 1 5004 or 5005 depending on operation mode 4 value zone 2 6001 5 setpoint zone 2 6004 or 6005 depending on operation mode 6 value zone 3 7001 7 setpoint zone 3 7004 o...

Page 9: ...2 Clock 13 Alarm text 14 Internal temperature 15 External temperature 16 Relative humidity 17 Digital input 1 18 Digital input 2 4001 Selection R W Contents of small digits 0 empty 1 text string OFF 2...

Page 10: ...xt string group 1 2 value 3 setpoint Comfort standby depending on operation mode 4 Alarm text 5 internal NTC 6 external NTC 7 humidity value 8 digital input 1 9 digital input 2 5004 16 bit signed R W...

Page 11: ...byte R W Digital input 1 open character 02 O 10304 byte R W Digital input 1 open character 03 F 10305 byte R W Digital input 1 open character 04 F 10306 byte R W Digital input 1 closed character 01 1...

Page 12: ...yte R W FAN string 2 character 4 1 11008 byte R W FAN string 3 character 1 F 11009 byte R W FAN string 3 character 2 A 11010 byte R W FAN string 3 character 3 N 11011 byte R W FAN string 3 character 4...

Reviews: