background image

13

2 YEAR LIMITED WARRANTY PROGRAM

This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of
Vector Products, Inc., regarding this product. There is no other warranty, other than those described herein.

This Vector Products, Inc. product is warranted, to the original purchaser only, to be free of defects in materials and
workmanship for two years from the date of purchase without additional charge.  The warranty does not extend to
subsequent purchasers or users. Vector Products, Inc. will not be responsible for any amount of damage in excess
of the retail purchase price of the product under any circumstances. Incidental and consequential damages are
specifically excluded from coverage under this warranty.

This product is not intended for commercial use. This warranty does not apply to accessories or damage to units from
misuse or incorrect installation. Misuse includes wiring or connecting to improper polarity power sources.

RETURN/REPAIR POLICY:

Defective products, other than accessories, may be returned postage prepaid to

Vector Products, Inc.. Any defective product, other than accessories, that is returned to Vector Products, Inc. within 
30 days of the date of purchase will be replaced free of charge. If such a product is returned more than 30 days
but less than two years from the purchase date, Vector Products, Inc. will repair the unit or, at its option, replace it
free of charge.

If the unit is repaired, new or reconditioned replacement parts may be used, at Vector Products, Inc.’s option. 
A unit may be replaced with a new or reconditioned unit of the same or comparable design. The repaired or
replaced unit will then be warranted under the terms of the remainder of the warranty period. The customer is
responsible for the shipping charges on all returned items after 30 days. During the warranty period, Vector
Products, Inc. will be responsible for the return shipping charges.

LIMITATIONS:

This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting from normal

wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage or exposure to sunlight), 
accidents, damage during shipping to our service facility, alterations, unauthorized use or repair, neglect, misuse,
abuse, failure to follow instructions for care and maintenance, fire, flood and Acts of God.

If your problem is not covered by this warranty, call our Technical Support Department at Toll Free at 
(800) 544-6986 for general repair information and charges if applicable.

STATE LAW RIGHTS:

This warranty gives you specific legal rights. Some states do not allow limitations on how

long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the
exclusions or limitations stated herein may not apply. This warranty gives the purchaser specific legal rights; other rights,
which vary from state to state, may apply.

TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT:

Contact Technical Support by telephone, fax or

mail. We suggest that you keep the original packaging in case you need to ship the unit. When returning a product,
include your name, address, phone number, dated sales receipt (or copy) and a description of the reason for return
and product serial number. After repairing or replacing the unit, we will make every effort to return it to you within
four weeks.

WARRANTY ACTIVATION:

Please complete Warranty Activation Card and mail to Vector Products, Inc.. Enter 

“VEC053D” as Model and “MAXX SST

TM

1,200 WATT COMPACT POWER INVERTER” as Product Type. All Vector

Products, Inc. products must be registered within 30 days of purchase to activate this warranty. Mail the completed
registration form, along with a copy of the original sales receipt to:

IMPORTED BY:

VECTOÍR PRODUCTS, INC.

701 EAST JOPPA ROAD, TOWSON, MD 21286

• TOLL FREE: 1-800-544-6986 •

WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.

 90548014 VEC053D INVERTER.qxp  3/6/09  10:13 AM  Page 13

Summary of Contents for MAXX SST VEC053D

Page 1: ...OWNER S MANUAL WARRANTY INFORMATION TUFGG Lantern Cordless Rechargeable VEC053D MAXX SSTTM 1 200 WATT COMPACT POWER INVERTER IF YOU HAVE A QUESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS IMPORTANT...

Page 2: ...operation is dusty This applies to all persons in the work area Also use a hard hat hearing protection gloves safety shoes and dust collection systems when specified or required Safety glasses or the...

Page 3: ...ground Keep in mind that this inverter may not operate very high wattage appliances or equipment that produce heat Refer to Appliance Consumption chart in this manual Do not open the inverter there ar...

Page 4: ...r load or over temperature condition or abnormal input voltages The ON OFF Switch turns the inverter ON and OFF The switch can also be used to force reset of inverter circuits by switching it OFF then...

Page 5: ...the output voltage of this unit use a true RMS reading voltmeter such as a Fluke 179 Fluke 79 III series Beckman 4410 or Triplett 4200 Modified Sine Wave and Sine Wave Comparison Incompatible Products...

Page 6: ...ter can deliver on a continuous basis CAUTION TO REDUCE THE RISK OF PROPERTY DAMAGE Ensure that total continuous power consumption of all tools and or appliances connected to the inverter and in use d...

Page 7: ...inverters have a peak watt power rating many such appliances and tools may be safely operated The equipment that needs the highest starting wattage are pumps and compressors that start under load This...

Page 8: ...the low voltage alarm sounds when the battery is fully charged refer to the Troubleshooting section of this Instruction Manual CIRCUIT PROTECTION The inverter has electronic circuit protection against...

Page 9: ...to be sure the inverter s ON OFF Power Switch is in the OFF position and that no flammable fumes are present 2 Locate the Positive POS and Negative NEG terminals on the 12 Volt DC battery or other 12...

Page 10: ...ultaneous operation of all the AC appliances to be powered with delay characteristics that allow for the momentary high start up current requirements of inductive loads Use the specified fuse block fu...

Page 11: ...tion Buzzing sound in audio systems Some inexpensive stereo systems and boom boxes emit a buzzing sound from their speakers when operated from the Power Inverter This occurs because the power supply i...

Page 12: ...he DC power fuse 3 Check and tighten all electrical connections including the ground 4 Using a non metallic vacuum cleaner hose vacuum the air slots and fan area 5 Clean the outside of the unit using...

Page 13: ...m continuous power 1200 watts Surge capacity peak power 2400 watts Output voltage range 105 125 volts Output frequency 58 62 Hz Output voltage 120 VAC Maximum efficiency _ 87 Full load efficiency _ 82...

Page 14: ...Vector Products Inc will be responsible for the return shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear incl...

Page 15: ...TILISATEUR ET INFORMATIONS RELATIVES LA GARANTIE TUFGG Lantern Cordless Rechargeable VEC053D MAXX SSTTM CONVERTISSEUR CONTINU ALTERNATIF COMPACT DE 1200 W POUR TOUTE QUESTION OU TOUT COMMENTAIRE APPEL...

Page 16: ...TILISER DES LUNETTES DE S CURIT ET TOUT AUTRE QUIPEMENT DE S CURIT Utiliser des lunettes de s curit ou des lunettes coques conformes aux normes en mati re de s curit et le cas ch ant un protecteur fac...

Page 17: ...liser le convertisseur continu alternatif dans un endroit bien ventil Ne pas bloquer les fentes de ventilation TOUJOURS mettre le convertisseur continu alternatif HORS TENSION en le d branchant de la...

Page 18: ...ppareil Examiner les indications d avertissement appos es sur ces produits et sur le moteur INTRODUCTION Nous vous remercions d avoir achet le convertisseur continu alternatif compact VEC053D MAXX SST...

Page 19: ...it identifi e et corrig e PRINCIPE DE FONCTIONNEMENT Le convertisseur continu alternatif MAXX SST convertit les 12 volts c c courant continu d une batterie de v hicule ou d une autre source d alimenta...

Page 20: ...produit imm diatement et le d brancher du convertisseur continu alternatif CONSOMMATION NERG TIQUE DES APPAREILS LECTRIQUES Les convertisseurs continu alternatif MAXX SST sont id aux pour alimenter L...

Page 21: ...INTENSIT PUISSANCE 120 V C A 120 V C A Ordinateur portatif 0 45 55 Malaxeur lectrique domestique 1 83 220 Cha ne st r ophonique amplificateur de 240 W 2 01 242 R frig rateur 2 75 330 Perceuse r gime v...

Page 22: ...essay en toute s curit Si une surcharge est d tect e les convertisseurs continu alternatif se mettent simplement hors tension jusqu ce que la situation de surcharge soit rectifi e Pour r enclencher le...

Page 23: ...s est produite entre la source d alimentation par batterie et le convertisseur continu alternatif Remarques C est normal que l avertisseur du convertisseur continu alternatif sonne lors du branchemen...

Page 24: ...er d articles sur ou sous le convertisseur continu alternatif en cours de fonctionnement Les convertisseurs continu alternatif MAXX SST g n rent de la chaleur en cours de fonctionnement et doivent tre...

Page 25: ...is et des dispositifs de s curit sur la source d alimentation de 12 volts c c doit tre effectu e par un installateur professionnel Voici des exigences suppl mentaires 1 Le convertisseur continu altern...

Page 26: ...ns les endroits qui satisfont aux crit res suivants SECS ne pas mettre le convertisseur continu alternatif en contact avec de l eau ou d autres liquides FRAIS la temp rature ambiante de fonctionnement...

Page 27: ...le convertisseur de radio de t l vision bourdonnement continu alternatif et l antenne Utiliser une antenne blind e Raccorder l antenne l amplificateur Probl me Solution Bourdonnement des cha nes haut...

Page 28: ...pr ventif suivant 1 teindre le convertisseur continu alternatif l aide du commutateur d alimentation MARCHE ARR T sur la face avant 2 Retirer le fusible c c 3 V rifier et serrer toutes les connexions...

Page 29: ...batteries les d fauts r sultant de l usure normale y compris les clats les gratignures les abrasions les d colorations ou le p lissement caus par l utilisation ou l exposition aux rayons du soleil le...

Page 30: ...INFORMACI N SOBRE LA GARANT A TUFGG Lantern Cordless Rechargeable VEC053D CONVERSOR EL CTRICO COMPACTO DE 1200 VATIOS MAXX SST SI TIENE ALGUNA PREGUNTA O DESEA HACER ALG N COMENTARIO LL MENOS SU OPIN...

Page 31: ...de ser necesario un protector facial Use tambi n m scaras faciales o para polvo si la operaci n produce polvillo Esto se aplica a todas las personas que se encuentren en el rea de trabajo Use tambi n...

Page 32: ...ible se queme y puede causar un da o permanente al conversor y anular la garant a La mayor a de los autom viles modernos veh culos recreativos y camiones posee un negativo a tierra Tenga en cuenta que...

Page 33: ...e arranque de cargas inductivas grandes pod an apagar un conversor La SST mejora el funcionamiento del conversor ya que brinda Ascenso gradual del voltaje durante el arranque del conversor que elimina...

Page 34: ...co La forma de onda de salida del conversor el ctrico La forma de onda de salida de CA del conversor el ctrico se conoce como onda senoidal modificada Es una forma de onda que posee caracter sticas si...

Page 35: ...el consumo de potencia de la carga por 10 Por ejemplo si el valor nominal de una carga de CA es de 200 vatios la fuente de energ a debe suministrar 200 dividido 10 20 amperios El conversor cuenta con...

Page 36: ...ipos con motor requieren un ascenso muy pronunciado de la tensi n para arrancar Posiblemente el conversor no logre encender algunos de estos motores incluso si su consumo de corriente calificado se en...

Page 37: ...Por ejemplo una cafetera t pica para uso dom stico consume 500 vatios durante el tiempo de preparaci n aproximadamente 5 minutos pero conserva la temperatura de la cafetera a s lo 100 vatios aproxima...

Page 38: ...ue la prueben y reparen t cnicos profesionales de la f brica INSTALACI N Los conversores MAXX SST le brindar n energ a el ctrica de forma continua si se utiliza una fuente de CC de 12 voltios como una...

Page 39: ...cuando el primer cable toque el terminal de la bater a ADVERTENCIA Si se produce un arco importante y continuo entre los terminales de los cables y de la bater a interrumpa de inmediato el trabajo de...

Page 40: ...tarse directamente a equipos el ctricos y electr nicos est ndar de la forma en que se describi anteriormente No conecte el conversor el ctrico a cableados de distribuci n de CA de veh culos recreativo...

Page 41: ...por el conversor La nica soluci n a este problema es utilizar un sistema de sonido de calidad superior que incorpore una fuente amplificada de energ a de mejor calidad Interferencia con el televisor...

Page 42: ...s las conexiones el ctricas incluida la conexi n a tierra 4 Con la manguera no met lica de una aspiradora aspire el rea de las ranuras y del ventilador 5 Limpie la parte externa de la unidad con un pa...

Page 43: ...ensi n potencia pico 2400 vatios Rango del voltaje de salida 105 a 125 voltios Frecuencia de salida 58 a 62 Hz Voltaje de salida 120 V de CA Eficiencia m xima _ 87 Eficiencia m xima de la carga _ 82 C...

Page 44: ...as defectos que resulten del uso y desgaste normales que incluyen melladuras rasgu os raspaduras manchas o p rdida de color debido al uso o a la exposici n a la luz solar accidentes da os durante el e...

Reviews: