8.1

AC Recharge

Recharge requires the use of the supplied VEC077EM Automatic Battery

Charger. The charger must be powered from a 110 volt AC, 60 Hz North

American standard household AC receptacle. Typical recharge time is ten

hours.

CAUTION:

 NEVER OPERATE THE VEC077EM CHARGER FROM ELECTROMATE’S

POWER INVERTER. THERE IS NO SUCH THING AS A PERPETUAL MOTION

MACHINE. HEAT WILL BE GENERATED AND THERE WILL BE A NET LOSS OF

BATTERY ENERGY. YOU CAN POWER MOST OTHER APPLIANCE CHARGERS

FROM THE POWER INVERTER. The battery charger is stored in the Charger

Storage Hatch. Always remove the charger for use. Connect the red and

black DC cable connector to the mating connector stored inside the charger

storage hatch. The charger must be operated on a flat stable surface with free

air space around it. (See Figure 8.) Keep charger 18 inches from the floor.

FIGURE 8

 – BATTERY CHARGER HOOKED TO ELECTROMATE

WARNING:

 NEVER OPERATE THE CHARGER INSIDE THE CHARGER

STORAGE HATCH - IT WILL OVERHEAT AND SHUT DOWN. POSSIBLE

DAMAGE TO THE CHARGER MAY RESULT.

As recharge progresses, the battery level LEDs will light one by one. Charge

the ElectroMate until the Battery Status Display lights the FULL LED. Continue

to recharge until the battery is fully charged. The charger is fully automatic

and it can be left connected to ElectroMate indefinitely.

The charger can be connected to the supplied battery clamp adapter cable for

directly charging a battery in a vehicle, boat or other engine starting battery.

For complete operation of the VEC077EM charger away from ElectroMate,

refer to the manual supplied with the charger. To ensure rapid charging of the

battery, make sure that the inverter, compressor and lamp are turned off

during recharging.

8.2

DC Recharge

During an emergency when AC is not available to power the VEC077EM

Automatic Battery Charger, DC charging is an option. Recharging ElectroMate’s

internal battery from an external DC power source requires the use of the

Jumper Cables. It is recommended that the engine be left running so the vehicle’s

battery is not discharged.

CHARGER

HATCH

CONNECTOR
PAIR

Summary of Contents for ElectroMate VEC095

Page 1: ...AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 110 Volt AC 12 Volt DC Portable Power Supply VEC095 Electronic Gen...

Page 2: ...le battery is jump started Before jump starting this type of vehicle read the vehicle s owner s manual to confirm that external starting assistance is advised 11 Excessive engine cranking can damage t...

Page 3: ...Tips 12 5 7 Troubleshooting the Inverter 12 6 COMPRESSOR TIRE INFLATOR 12 6 1 Compressor Use 13 6 2 Compressor Safety Information 13 6 3 Inflation of Tire or Products with a Valve Stem 13 6 4 Typical...

Page 4: ...ccessories This ElectroMate model is modular in design and can be considered as several interconnected components The major components are Battery Power Inverter Automatic Battery Charger Tire Compres...

Page 5: ...I outlets can connect to any two or three pin North American standard appliance plugs ElectroMate is also ideal to power 12 Volt DC cordless portable appliances with a combined current rating up to 30...

Page 6: ...rage Hatch and must be removed from the Storage Hatch for use The VEC077EM is a high frequency three stage charger that can either be permanently connected to ElectroMate or connected to a battery cla...

Page 7: ...Battery Status Button Polarity Correct LED indicates when it s safe to turn on the Safety Switch Audible alarm sounds when polarity is incorrect Visual LED Alarm indicates Reverse Polarity Adjustable...

Page 8: ...start Procedure 1 Make sure the ElectroMate Safety Switch is turned OFF enabling the reverse polarity alarms and correct polarity indicator 2 Turn Off ignition and all accessories radio A C lights et...

Page 9: ...FCI dual outlets 110 Volt 60 Hz AC alternating current household power It s DC source is the installed 12 Volt battery Safety features include an audible low battery alarm and automatic shutdown to pr...

Page 10: ...ied sine wave produced by the Power Inverter has an RMS root mean square voltage of 110 which is the same as standard household power Most AC voltmeters both digital and analog are calibrated for RMS...

Page 11: ...itor its temperature for the initial ten minutes of use to determine whether it becomes warmer than usual If excessive heat is generated it is a good indication that the device should not be used with...

Page 12: ...those that start under load such as compressors and pumps Testing is the only definitive way to determine whether a specific load can be started and how long it can run The unit will simply shut down...

Page 13: ...re with the pressure gauge Never leave compressor unattended while in use Allow unit to cool after 10 minutes of continuous operation 6 3 Inflation of tire or products with a valve stem 1 Place connec...

Page 14: ...ocation NOTE The lamp may be used with any 12 Volt DC source vehicle accessory socket that can supply at least one ampere This allows great flexibility in positioning the lamp during tire inflation an...

Page 15: ...STORAGE HATCH IT WILL OVERHEAT AND SHUT DOWN POSSIBLE DAMAGE TO THE CHARGER MAY RESULT As recharge progresses the battery level LEDs will light one by one Charge the ElectroMate until the Battery Sta...

Page 16: ...ry compartment cover Periodically the cables and connectors should be inspected for dam age corrosion dust and dirt If surfaces are dirty they can be wiped clean with a cloth moistened with water and...

Page 17: ...artment Lift the two cables out of the way so they are not down inside the battery compartment Carefully lower the battery into the battery compartment The terminals on the battery can be one of sever...

Page 18: ...extended and more permanent higher power loads WARNINGS Never use the jumper cables to connect to a battery that is not stationary vibration can shake loose the cable clamps A moving vehicle or boat c...

Page 19: ...er Green LED lit battery charged and no alarms sound Battery is charged but Loose battery connections Clean all contacts tighten won t handle large loads the post connectors and battery terminals Fluo...

Page 20: ...eneral repair information and charges if applicable STATE LAW RIGHTS This warranty gives you specific legal rights Some states do not allow limita tions on how long an implied warranty lasts or the ex...

Reviews: