Cleaning and Maintenance

WARNING: The unit uses a 230V  supply and contains rotating 
mechanical parts.

Before carrying out any maintenance or cleaning operations the 
mains electrical supply MUST be disconnected

.

To clean the filters and heat exchanger:

The air filters and heat exchanger of the Vectaire WHHR125DC- Aera 
should be cleaned regularly by a suitably qualified person (the frequency 
of cleaning will vary depending on the installation environment).

   Remove the access panel

  Slide out the filters that are fitted either side of the heat exchanger as

    shown. 

  Clean the filters carefully using a vacuum cleaner. 

  Carefully remove any dust from the face of the heat exchanger using a

    vacuum cleaner.

Never use water or any other fluids to clean the heat exchanger
•      

Return the heat exchanger and filters to their original position.

•      

Replace the front cover.

•      

Power to the unit can now be restored.

Filter Replacement

Filters should be replaced annually or after a maximum of 3 cleaning cycles.
Replacement filters are available from Vectaire- - call us on +44 (0) 1494 522333 or via [email protected]

Summary of Contents for WHHR125DC

Page 1: ...WHHR125DC Aera Residential Whole House Heat Recovery Unit with Low Energy DC Motor Installation Operating and Maintenance Instructions...

Page 2: ...the loft of a house or the void above the ceiling in an apartment or in a cupboard It will be connected by hidden ductwork to vents sited in the ceilings of the rooms which are to be ventilated Each...

Page 3: ...le or corrosive in ambient temperatures above 40 C or lower than 0 C in areas of excessive humidity or in a wet environment Where possible the unit should NOT be installed directly above a bedroom or...

Page 4: ...l mounting bracket 1 x Safety bracket 2 x 15mm Drain connectors 4 x M6 screws and wall plugs 1 x self tapping screw 1 x Installation Operation Maintenance Instructions Any parts shortages or faults mu...

Page 5: ...he interlocking side is at the top as shown 5 Mount the unit by locating the bracket on the back of the unit securely over the mounting bracket 6 Fix the lower safety bracket as shown Screw and plug s...

Page 6: ...hold drainage system via a U bend which must act as an air lock 7 The unit has two drain condensation outlets with two fittings and bungs to seal off one of the outlets 8 In UK climate conditions the...

Page 7: ...ical Connection WARNING these appliances must be earthed and all wiring must conform to current IEE Regulations and all applicable standards and Building Regulations The unit is suitable for 230V 50Hz...

Page 8: ...volumes will not always be equal When setting up therefore the extract system should be the datum Commissioning Procedure Ensure that the exhaust and supply grilles or valves are open Turn the electri...

Page 9: ...suitably qualified person the frequency of cleaning will vary depending on the installation environment Remove the access panel Slide out the filters that are fitted either side of the heat exchanger...

Reviews: