Page 3

Installation
IT Is IMPORTANT THEsE INsTRUCTIONs ARE READ FULLY BEFORE INsTALLATION

This product should not be used for any purpose other than that for which it was designed and as shown in 

this leaflet

All packaging should be removed and the unit checked for damage in transit.  If there is any damage, please 

contact your supplier

The WHHR100/90DC-B Plus Bypass will generally be fitted into a loft of ceiling void.  In order to comply 

with Construction (Design & Management) Regulations, sufficient access for safe maintenance (recom

mended on an annual basis),  or removal following installation, MUST be provided for this product.  See 

dimensions above.

Fire Dampers must be fitted to duct work at appropriate locations in accordance with Building Regulations

Flue gases from fuel-burning equipment must not be drawn into a living area.  If any room from which air is 

extracted contains a fuel burning appliance, such as a central heating boiler,  then its flue must be of the 

sealed or balanced flue type, or allowance must be made for an adequate supply of air into the room.

The unit is designed for horizontal installation and should be fitted with 2º tilt towards the condensation 

drain used

The unit must NOT be installed:

-

where there is excessive oil or grease

-

where there are hazardous gases, liquids or vapours that are flammable or corrosive

-

in ambient temperatures above 60ºC or lower than 5ºC

-

in humidity levels above 90% or in a wet environment

Where possible the unit should NOT be installed directly above a bedroom or living room.  

The condensation drain must be fitted and if insulated, use the equivalent of at least 25mm of insulating 

material with a thermal conductivity of 0.04 W/(mK)

Care should be taken to ensure that ducting is free from blockages before switching on the unit as this may

invalidate your guarantee

External grilles should be located a minimum of 600mm from any flue outlet in accordance with all 

Regulations

The unit must be connected to a 230-240v, 50Hz single phase electrical supply.  

•  A triple pole isolation switch with contact  separation of at least 3mm must be used to connect the appliance

to the fixed wiring when using the Switched Live. 

.• The product should only be connected to the mains electricity supply or electrical outlet if:

-

your electrical voltage and frequency correspond to those shown on the rating label.

-

the capacity of your electricity supply is sufficiently powerful to operate the product at its maximum 

power

If one of the spigots is not connected to ducting a safety grille MUST be fitted to that spigot, so that it is 

impossible for any moving part to be touched.

This appliance is not suitable for installation on the outside of a building.

Installation of the appliance MUST be carried out by a qualified and suitably competent person and should be

carried out in clean, dry conditions where dust and humidity are at minimal levels.  It should only be installed

after other building works have been completed and the building in which it is installed cleaned.  Failure to com-

ply with any of the above points will have an impact on the validity of the guarantee.

Summary of Contents for WHHR100

Page 1: ...WHHR100 90DC B Plus Whole House Heat Recovery Unit with Low Energy DC Motor for domestic and commercial use Installation Operating and Maintenance Instructions...

Page 2: ...nt avoiding the use of excessive energy and saving heat already generated The heat recovery unit will generally be installed in the loft of a house or the void above the ceiling in an apartment but ma...

Page 3: ...le the unit should NOT be installed directly above a bedroom or living room The condensation drain must be fitted and if insulated use the equivalent of at least 25mm of insulating material with a the...

Page 4: ...5mm of insulating material with a thermal conductivity of 0 04 W mK The pipe must drain into the normal household drainage system The drain must incorporate a wet or dry trap to prevent air penetratio...

Page 5: ...esign value If incorrect adjust as follows Turn the electrical supply off Remove the cover of the electrical control panel Adjust the potentiometer marked min up or down as required See page 6 Turn on...

Page 6: ...Page 6 Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494 522337 Email sales vectaire co uk WHHR100 90DC B Plus Oct 2014 E O E...

Page 7: ...WHHR100 90DC B Plus Bypass models Whole House Heat Recovery Unit with Low Energy DC Motor for domestic and commercial use Installation Operating and Maintenance Instructions...

Page 8: ...lthy environment avoiding the use of excessive energy and saving heat already generated The heat recovery unit will generally be installed in the loft of a house or the void above the ceiling in an ap...

Page 9: ...ssible the unit should NOT be installed directly above a bedroom or living room The condensation drain must be fitted and if insulated use the equivalent of at least 25mm of insulating material with a...

Page 10: ...5mm of insulating material with a thermal conductivity of 0 04 W mK The pipe must drain into the normal household drainage system The drain must incorporate a wet or dry trap to prevent air penetratio...

Page 11: ...am A green light will appear on the circuit board 3 With the boost switch OFF bathroom light switch off measure the airflow rate at the extract valve and compare this to the design value If there is a...

Page 12: ...valve Boost speed l h drainage 6 Switch on the boost light switch ON 7 Measure the airflow rate at the extract valve and compare this to the design value If there is a difference adjust the potentiom...

Page 13: ...ain access panel Remove the rubber inserts from the filter slots where fitted and slide out the filters from the internal mouldings Clean the filters carefully using a vacuum cleaner and refit Replace...