background image

Page 3

Installation
IT Is IMpORTAnT THEsE 
InsTRUCTIOns  ARE  READ
FULLY BEFORE 
InsTALLATIOn

This product should not be 
used for any purpose other 
than that for which it was de-
signed and as shown in this 
leaflet

All packaging should be re-
moved and the unit checked 
for damage in transit.  If 
there is any damage, please 
contact your supplier

The Mini DC will normally be 
fitted into a loft or ceiling void.

In order to comply with Construction (Design & Management) Regulations, sufficient access for safe
maintenance (recommended on an annual basis),  or removal following installation, MUsT be 
provided for this product.  We recommend that a clearance of at least 150mm is available on each 
side of the cabinet to allow access to the motors.  see dimensions diagram.

Regulations and current Building Regulations.  In order to comply with these, it may be necessary to fit fire
dampers or other similar devices.

Flue gases from fuel-burning equipment must not  be drawn into a living area.  If any room from which
air is extracted contains a fuel burning appliance, such as a central heating boiler, then its flue must
be of the sealed or balanced flue type, or allowance must be made for an adequate supply of air into 
the room.

The unit must

nOT

be installed:

-

where there is excessive oil or grease

-

where there are hazardous gasses, liquids or vapours that are flammable or corrosive

-

in ambient temperatures above 50ºC or lower than 5ºC

-

in humidity levels above 90% or in a wet environment

Where possible the unit should 

nO

T be installed directly above a bedroom or living room.  

The condensation drain 

MUsT

be fitted

Care should be taken to ensure that ducting is free from blockages

External grilles should be located a minimum of 600mm from any flue outlet in accordance with all 
Regulations

The unit must be connected to a 230-240v, 50Hz single phase electrical supply.  

•    A triple pole isolation switch with contact  separation of at least 3mm must be used to connect the 

     appliance to the fixed wiring when using the Switched Live. 

    The product should only be connected to the mains electricity supply or electrical outlet if:

     -    your electrical voltage and frequency correspond to those shown on the rating label.
     -    the capacity of your electricity supply is sufficiently powerful to operate the product at its maximum 

          power.

    If one of the spigots is not connected to ducting a safety grille 

MUsT 

be fitted to that spigot, so that it is 

     impossible for any moving part to be touched.

Installation of the appliance 

MUsT

be carried out by a qualified and suitably competent person and should be 

carried out in clean, dry conditions where dust and humidity are at minimal levels. The unit is not suitable for 
installation to the exterior of the dwelling.

Transportation, packaging and storage prior to installation

•    Care should be taken when transporting the unit Dropping or knocking will damage the inner workings

     of the unit.

•    The unit should always be stored in a clean, dry environment.
•    Remove all packaging before installation.

pre-inspection

•    Inspect the unit and electrical supply cord for any damage (damage must be repaired by a suitably 

     qualified and competent person.)