16
©Vecow RMS-1000 User Manual
GETTING TO KNOW YOUR RMS-1000
2.6.2 Ignition Control Wiring
To activate ignition control, you need to provide IGN signal via the 3-pin
pluggable terminal block locates in the back panel. Please find below the
general wiring configuration
For testing purpose, you can refer to the picture blow to simulate ignition signal
input controlled by a latching switch.
Note :
1.
DC power source and IGN share the same ground.
2.
RMS-1000 supports 9V to 48V wide range DC power input in ATX/AT mode. In
Ignition mode, the input voltage is fixed to 12V/24V for car battery scenario.
3.
For proper ignition control, the power button setting should be "Power Down" mode.
Pin No.
Definition
1
Ignition (IGN)
2
SW+
3
SW-
IGN
IGN
V+
V-
In Windows for
example, you need
to set "When I press
the power button" to
Shut down.