4.0 WARRANTY AND SERVICE POLICIES 

4.1 Warranty Statement

 

Vecima Networks warrants its products to be free from defects in workmanship or materials for a period 
of two years.  The warranty begins on the date of the original shipment from Vecima Networks to its 
customer.  No claim may be allowed for expenses incurred in installation or use.  No other expressed or 
implied warranties shall apply to the goods sold. Vecima Networks is not responsible for delayed 
shipments, other loss beyond Vecima Networks’ control, or consequential damages of any kind arising 
in connection with the use of its products.  This warranty is a return-to-factory warranty only.  During the 
warranty period Vecima Networks will at its option, replace, repair or refund the price paid for any item 
which is returned for service.  This warranty does not apply to units that have been physically or 
environmentally abused. 

 

4.2 Service Policies: How to Return an Item for Service:

 

Before returning any item for service, an R.M.A. (Returned Material Authorization) number must be 
assigned by Vecima Networks.  A unique R.M.A. number will be assigned for each item being returned. 
 When requesting an R.M.A. number, please be prepared to provide the model, Vecima Networks serial 
number, original invoice number, your purchase order number and an adequate fault description.  The 
serial number of a unit can be found on a barcode label similar to the one pictured below.  R.M.A. 
service is available Monday to Friday from 8:30 a.m. to 4:30 p.m. CST (statutory holidays excepted). 

 

 

 

 

To obtain an R.M.A. number you may: 

Call: (306) 955-7075, press ‘0’ for Operator, or ‘3’ for Service Dept. 

Fax: (306) 384-0086 — Attention: R.M.A. Request 

Email: [email protected] 

 

Once an R.M.A. number has been assigned, please refer to it in all correspondence and make certain 
that all applicable R.M.A. numbers are clearly marked on the outside of each package being returned.  
You must also ensure that each product is shipped to Vecima Networks in its original shipping container 
(or equivalent) via Prepaid carrier, with appropriate insurance and customs documentation (where 
required).  Vecima Networks will not accept collect shipments, damaged shipments or shipments 
unaccompanied by an R.M.A. number. 

 

For items still under Warranty

 – Items will be returned from Vecima Networks Inc. to its customer via 

prepaid ground carrier.  The customer is responsible for any additional costs incurred, including custom 
clearance and duties.  Any alternate means of shipment must be requested by the customer and will be 
subject to additional charges.  

 

For items no longer under Warranty

 – Items will be returned from Vecima Networks Inc. to its 

customer via prepaid ground carrier at the customer’s expense.  The customer is responsible for any 
additional costs incurred, including custom clearance and duties.  Any alternate means of shipment 
must be requested by the customer and will be subject to additional charges. 

 

Shipping Instructions will be provided by the repair center when the RMA number is sent to the 
customer. 

Summary of Contents for TRI2525B

Page 1: ...TRI2525B 2 5 2 6 GHZ SERIES BROADBAND WIRELESS TRANSCEIVER INSTALLATION AND OPERATION GUIDE...

Page 2: ...reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of Vecima Networks Inc to provide notification of such revision or change...

Page 3: ...All Vecima Networks products benefit from this ground breaking expertise Vecima Networks designs and manufactures z 256 QAM Upconverters z Digital Video Modulators z Agile CATV Modulators z Frequency...

Page 4: ...connect or disconnect cables during periods of lightning activity LES PR CAUTIONS DE S CURIT 1 Avant d installer ou d op rer cet quipement lisez toutes les sections de s curit s d installations et d o...

Page 5: ...2 Mounting the Unit 9 2 3 Connection to the Power Inserter and Cable Modem 13 2 4 Waterproofing Connections 14 3 0 ALIGNING THE ANTENNA 16 3 1 Preparation for Tuning 16 3 2 Signal Strength and Alignme...

Page 6: ...tri2525b_ml_03_sd Approved G V vi Vecima Networks Inc...

Page 7: ...w cost 75 ohm cable i e RG 59 RG 6 or similar A single RF F connector on the weatherproofed enclosure provides the interface to the transmit receive antenna for rapid installation 1 2 Module Features...

Page 8: ...z band 0 5 dB IF Output Frequency Range 534 to 564 MHz Noise Figure 5 5dB typical 7 dB max including narrowband duplexer loss Integrated Gain 44 1dB Input Third Order Intercept Point 7 dBm at LNA inpu...

Page 9: ...nsure that the pole used is attached securely to the building or other mounting location Step 1 Attach L Bracket to TRI2525B Before the unit can be attached to the pole the L bracket must be attached...

Page 10: ...sd Approved G V 10 Vecima Networks Inc DIAGRAM 2 2A L BRACKET ORIENTATION Once the L bracket is in place the unit can be mounted to the pole The pole catch V bolt and L bracket are oriented as shown i...

Page 11: ...AM 2 2B TRI2525B MOUNTED TO POLE Horizontal Alignment Vertical Alignment STEP 2 Position V bolt and pole catch around pole To attach the TRI2525B to the pole first position the pole catch over the thr...

Page 12: ...the L of the L bracket and not on the outside of the L This is necessary to maintain antenna alignment during high winds STEP 4 Tighten TRI2525B against pole Tighten both locknuts against the L brack...

Page 13: ...to wall adapter with the supplied RG 59 cable with F connectors TO MODEM Connect to cable modem install modem only after the antenna is aligned TO TRANSCEIVER Connect to TRI2525B WARNING If the power...

Page 14: ...he TRI2525B end stretch the tape and wrap it around the connector as close as possible to the wall of the TRI2525B Overlap the tape by approximately one half of its width so that it can form a seal wi...

Page 15: ...tri2525b_ml_03_sd Approved G V 15 Vecima Networks Inc When done the connection should be tightly wrapped with tape with a good seal to the cable...

Page 16: ...5B in the general direction of the hub site then move it to maximize the rate of the beeper The highest rate heard represents the highest receive signal level and the best alignment Once the antenna a...

Page 17: ...label similar to the one pictured below R M A service is available Monday to Friday from 8 30 a m to 4 30 p m CST statutory holidays excepted To obtain an R M A number you may Call 306 955 7075 press...

Page 18: ...the event that no fault is found the item is subject to the current Test Fee and will be exempt from warranty 5 Any product exhibiting external damage either from shipping improper handling or use wi...

Page 19: ......

Page 20: ...150 Cardinal Place Saskatoon Saskatchewan Canada S7L 6H7 Tel 306 955 7075 Fax 306 955 9919 Web www vecimanetworks com Email sales vecimanetworks com...

Reviews: