Installation
Mounting
Specifications
Maintenance
Overheating
1. The distances shown in the above sketch are minimum.
Distances less than shown may cause fire.
2. The connection box must always be positioned upwards.
3. The heater must not be covered or tampered, to avoid overheating, fire or electric shock.
No maintenance is required except a periodic functional test and cleaning.
* Without air deflector. The air deflector will add 45mm to D.
The heater is thermally protected by an overheat cut-out with manual reset,
with the reset button placed on the lid of the connection box.
> 1800 mm
> 300 mm
> 300 mm
> 300 mm
> 1800 mm
> 2500 mm
> 2500 mm
W
H
D
A
B
> 1800 mm
> 300 mm
Type
ENV 2 ENV R2 ENV 3 ENV R3 ENV 5 ENV R5 ENV 9 ENV R9 ENV 15 ENV R15 ENV 20 ENV R20 ENV 30 ENV R30
Rated voltage
Rated power
Reduced power
Rated current
A
B
W
H
D*
285 mm
400V 3N~ 50Hz
15 kW
7.5 kW
21.7 A
157 mm
350 mm
10 kW
29.0 A
220 mm
470 mm
418 mm
520 mm
115 mm
270 mm
235 mm
310 mm
150 mm
9 kW
5 kW
115 mm
115 mm
157 mm
230V~ 50Hz
2 kW
1 kW
8.7 A
230V~ 50Hz
400V 3N~ 50Hz
400V 3N~ 50Hz
400V 3N~ 50Hz
1.5 kW
3.3 kW
6 kW
20 kW
3 kW
30 kW
400V 3N~ 50Hz
20 kW
220 mm
13.0 A
7.2 A
13.0 A
43.5 A
270 mm
470 mm
235 mm
310 mm
150 mm
270 mm
235 mm
310 mm
150 mm
418 mm
520 mm
332 mm
350 mm
310 mm
400 mm
190 mm
332 mm
310 mm
405 mm
5
1. The
and
heater series are approved for installation in dry, damp or wet rooms
but not in environments where there is risk for fire or explosion.
2. The heater must be connected to the mains supply with a fixed installed round cable, which
ensures that the electrical protection class of the heater is retained.
3. An all phase breaker with a contact gap of at least 3mm must be included in the fixed
installation.
4. The installation must be carried out by an authorized electrician.
5. The heater is S-marked, CE-marked, EMC-marked and designed in accordance with the
following standards:
/ EN 61000-3-2
.
6. The heater must not be located immediately below a socket outlet.
ENV
ENV R
EN 60335-1 / EN 60335-2-30
/ EN 61000-3-3 / EN 61000-6-2 / EN 61000-6-3
ENV / ENV R