background image

MOUNTING HEIGHTS

ALL MEASUREMENTS IN MM FROM CENTER OF 
HINGE

Max. 4m

PHV

 360

115°

PHV

 240

110°

HEAVY

800KG

PHV

 360

90°

PHV

 240 - 95°

PHV

 360 -115°

PHV

 240

110°

MED.

600KG

PHV

 360

95°

PHV

 240 - 95°

PHV

 360 -115°

PHV

 240

110°

LIGHT

400KG

Max. 6m

Max. 2m

MAX.

HEIGHT

Fig..1

Fig..2

Fig..3

Ed1. 14/12/09 (

English)

5 of 10

M

A

B

C

85°

195

185

90

90°

180

180

90

95°

165

180

90

100°

150

180

90

105°

140

180

90

110°

125

180

90

115°

115

180

90

120º

105

180

90

M

A

B

C

85°

200

180

100

90°

180

180

100

95°

165

180

100

100°

150

180

100

105°

125

180

100

INWARD OPENING (Fig.2)

OUTWARD OPENING (Fig.3)

PHV

 3

6

0

M

A

B

C

85°

130

125

70

90°

120

120

70

95°

110

120

70

100°

100

120

70

105°

93

120

70

110°

85

120

70

115º

85

115

70

M

A

B

C

85°

130

120

80

90°

120

120

80

95°

110

120

80

100°

100

120

80

INWARD OPENING (Fig.2)

OUTWARD OPENING (Fig.3)

PHV

 24

0

Summary of Contents for PHV 240

Page 1: ...INSTRUCTION MANUAL HYDRAULIC GAT E PHV 240 PHV 360 Ed1 14 12 09 Italiano...

Page 2: ...matic weighing machinery terminal telecommunication equipment and electrical material destined for use with specific voltage limits 2004 108 EEC Council Directive amending Directive 89 336 EEC on appr...

Page 3: ...ath for which the manufacturer will not be held responsible For protection against electrical overload or short circuit always install a 0 03 amp differential and a thermal magnetic switch with a cont...

Page 4: ...eight 11 Kg 12 Kg PHV TECHNICAL DATA 230V 50HZ 276 W 1 3 A 16 uf 100 C 15 to 80 C 50 bar 0 to 7793 N 795Kg 0 to 6252 N 638Kg Dimensions PHV240 PHV360 A 985 mm 1225 mm B 915 mm 1155 mm C 673 mm 793 mm...

Page 5: ...lied to graph1 the maximum time of use for model 240 is 2h 15min and for 360 is 1h 30min Considering the quotas model 240 should be used 4 of 10 E G Model 360 E G Model 240 Graph 1 Graph 2 0 1h 2h FRE...

Page 6: ...10 M A B C 85 195 185 90 90 180 180 90 95 165 180 90 100 150 180 90 105 140 180 90 110 125 180 90 115 115 180 90 120 105 180 90 M A B C 85 200 180 100 90 180 180 100 95 165 180 100 100 150 180 100 105...

Page 7: ...ge 5 These values should be as near as possible to those determined by the thick vertical line The dimension for C is constant at C 90 mm for model 360 and C 70 mm for model 240 Example What should be...

Page 8: ...Fig 12 Fig 11 Fig 10 Fig 9 Fig 8 Fig 7 Fig 6 Fig 5 Fig 4 Fig 3 Fig 2 Fig 1 MOUNTING INSTRUCTIONS 7 of 10 Ed1 14 12 09 English...

Page 9: ...arm Fig 9 Page 7 up to the front cover plate fixing its position with the Allen key The hydraulic transmission can then be plugged in and started Re position the collar stopper to the desired positio...

Page 10: ...c system turn the valve clockwise IMPORTANT If the valve is not tight the motor will not function BLOCKING FUNCTION ADJUSTMENT OF BAC VALVES Red open Blue closed Opening blocked and closing reversed R...

Page 11: ...50171 15 Hingee set with nut A232 11003 K1 Aluminium coverPHV240 70044 16 Condenser 16 Uf 80497 Aluminium cover PHV360 70197 Door support kit 240 A232 11001 K1 5 End cover for aluminium arm cover 700...

Reviews: