vds EURO24PR Instruction Manual Download Page 2

OPTIONS SELECTOR

The maneuvers are executed through the Alternative button (Test button on the motherboard, or Alternative switch terminals, or by radio card).
The maneuvers ends for one of the following conditions: activation of the corresponding end switchs orby the end of operating time.
If during the opening operation is given an order, the action is stoped and do not run the closing.
Stop button activation causes immediate stop of the maneuver, requiring an order for the resumption of it.
Activation os safety switch input during closing, inverts it and goes to open position.
Input battery alimentation.
Garage light is activated during 0.5 sec. before starting the opening operation and is turned off 2 sec. after it.
Courtesy light at the opening (if allowed) flashes slowly, and on closing flashes quickly. In open position courtesy light is ON.
Drive power regulation selected in R. FORCE, it will be applied after 2 sec. Of the maneuvre.

OPERATING INSTRUCTIONS

Instruction Manual

In order to program functions the control panel should be in a stable state with the door closed.
Option number 3 must be turned OFF. If we want buffer closing I7 must be turned ON and if we have an encoder DIP switch number 8 must be turned ON too.
Push button PROG TIEMPOS  for 1,5 secs. The red LED will light up indicating that the panel is ready for time programming. Now we can proceed. In order to stop
programming press button PROG for 1,5 secs again with the door in 'resting' position; the process requires that a full opening and closing cycle is completed.
To program working times with pedestrian button press PROG button for 1

-

5s

-

Let and press the button for 1.5s and programming LED will turned ON.  With pedestrian

Button we will start the programming time function

-

Programming times process

1) The door must be closed. Activate as described above. The red LED lights up.
2) Push "START" button to open the door.
Pushing "START" again will stop the door and will memorize the time of opening. If opening is finalized by limit switch open (LSO), the programme will memorise times
+ 4 sec.
3) Once the door is open, the closing time will be memorized automatically until the closing operation has begun.
4) Push"START" button to close the door.

I7 OFF -

Pushing "START” again will stop the door and memorize the closing time. If closing is finalized by limit switch (LSC), the programme will memorise

times + 4 sec.

I7 ON -

Pushing "START” button again, drive reduce the speed (buffer closing), and pressing it again, the manoeuvre will stop and closing time, and buffer

closing will be memorized. If the manouvre is finalized by limit switch open (LSO), the programme will memorise times + 4 sec.

5) Upon completing a full cycle of the door programming will be automatically finalized.

The maximum memorization time is 2 minutes, if you wait more, this limit will be memorized.

DIGITAL PROGRAMMING

of open, close & automatic close.

GB

OPTION 1 - Sectional / Sliding Gate

OPTION

ON

Door closes automatically after waiting the a.c. time.

OFF

Door does not close automatically.

OPTION

ON

Alternative button stops and invert at close. Disable stop opening.

OFF

Alternative button stops.

OPTION

ON

Invert drive direction.

OFF

Normal drive direction.

OPTION 5 - Pneumatic Band with Stop Options

ON

Input Cseg1 works like security band, stopping opening and closing.

OFF

Input Cseg1 works like security band, stopping the closing and stop &
inverts 2 sec. in the opening.

OPTION 6 - Flashing Light

ON

Flashing

OFF

Fixed

OPTION 7 - Buffer Closing

ON

Drive reduce it’s speed at the end of opening & closing.

OFF

No buffer.

OPTION 8 - Enconder Yes/No

ON

Enable encoder input.

OFF

Disable encoder input.

ON

Sectional.

OFF

Sliding.

2 - Automatic Closing

3 - Door Stop & Inverts and Disable Stop Opening

4 - Drive Direction

OPTIONS SELECTOR

EURO24PR

CANCELLATION OF ALL CODES

- Here we have to reset the memory.
- Press PROG/RES for 3,5 seconds.
- After 1,5 seconds one acoustic signal will be heard indicating that you have entered the
code memorization mode, maintain the button pressed.
- After 3,5 seconds you will hear a series of acoustic signals.
- Stop pressing the button.
- The receptor will have cancelled all codes.
- The System stays in memorization mode, ready to receive new codes (see system a)

FIRMWARE

CODE MEMORITZATION

Manual memoritzation

- Press button PROG/RES for 1,5 sec.
- On hearing the acoustic signal stop pressing as the receptor will be logged onto the memorizing code
sequence. - From this moment received codes will be memorized.
- In order to memorize push any button on the transmitter.
- The memorization of a code is confirmed with one acoustic signal.
- The receiver will exit automatic memorization code sequencing after 10 seconds from the last code input. This will be indicated with two acoustic signals. Emergency
exist of the automatic memorization code sequencing can be done by pushing the special function button on one of the transmitters which is being coded (within 10
seconds).

Semiautomatic memorization

- In order to activate this system must have memorized at least one code into the receiver.
- Push the special function button on one of the transmitters which have been codified.
- On hearing one acoustic signal or when PROG led will turned ON, stop pushing and the receiver will have entered into code memorization
sequence. - From that moment.. follow the steps of manual memoritzation.