DIP SWITCHES FUNCTIONS
AUTOMATIC CLOSING:
Door closes automatically after waiting the a.c. time.
Door does not close automatically.
SAFETY FUNCTION (photocell):
ANALOG Contact (
8.2K
Ω
)
N.C Contact
(put a jumper if not used)
COURTESY LIGHT (LED
10)
:
Switched off
Switched on
(with sthe START command, LED work for 30 sec)
FLASHING LIGHT OUTPUT (LAMP RELAY):
Light blinks until the operator is running or waiting for automatic closing.
It turns off after 30 seconds the operator stop.
Light is fix until the operator is running or waiting for automatic closing.
It turns off after 30 seconds the operator stop
SLOW START CLOSING
The automation during closing start at slow speed.
The automation during closing start at normal speed.
OPERATOR RUNNING DIRECTION:
Normale polarity
Reversed polarity
1 2 3 4
ON ON ON ON
DIP 1
ON
OFF
LED MEANINGS TABLE
N° LED
DESCRIPTION
1
RADIO
2
CLOSE
3
OPEN
4
PROGRAMMING
5
START
N° LED
DESCRIPTION
6
PHOTOCELL
7
STOP
8
CLOSURE LIMIT SWITCH
9
OPENING LIMIT SWITCH
10
COURTESY LIGHT
5 6 7 8
ON ON ON ON
DIP 4
ON
OFF
DIP 5
ON
OFF
DIP 6
ON
OFF
DIP 7
ON
OFF
DIP 8
ON
OFF
FLASHING LIGHT CONNECTION
Flashing light output relay
(terminals 11-12)
+
1
2
V
LAMP
RELAY
Ground
Power supply
230V
L
N
LAMP
230V
11 12