Technical Data  

Installation depth 

50mm 

 
Operating Voltage  

12V System  

 8 – 16 Volt DC 

 

24V System 

18 – 32 Volt DC 

 
Accuracy  

< +/- 5 Sec / d (at 23°C) 

 
Current consumption  

< 10 mA, at 12V 

 

< 10 mA, at 24V 

 
Operating temperature 

-40°C to +85°C; plated bezels (chrome) -40°C to +70°C 

 
Storage temperature 

-40°C to +90°C for 48h; plated bezels (chrome) -40°C to +70°C 

 
Temperature shock 

Range 

-40°C to +85°C; plated bezels (chrome) -40°C to +70°C 

 

Transformation time  

10 seconds 

 Retention 

time 

 

2h 

 
Climatic test 

Range 

+25°C to +55°C  

 Rel. 

Humidity 

95% 

 
EMC in conformity with 

DIN_EN 61000-6-3 

 DIN_EN 

61000-6-1 

 DIN_EN 

61000-6-4 

 DIN_EN 

61000-6-2 

 
Standards EN 

60945 

 

GL, Category C, F (under preparation) 

 
Vibration 

Sinus 2g; 10-500Hz; duration 16h 

 

Noise 3g; 10-1000Hz, duration 8h 

 
Mechanical shock 

continuous 

25g; 6ms; 1Hz 

 

Single shock 

100g; 11ms 

 

Free fall 

1m; 3 times 

 
Chemical resistance against  - preservative agent 
 

- preservative agent remover 

 

- cold cleaner 

 

- methylated spirit 

 

- interior cleaner 

 

- drinks containing caffeine and tannin 

 
Nominal position 

NL 0 to NL 90 (DIN16257) 

 
Protection class  

according to IEC 60529 

 

Front: IP67 (in Nominal position) 

 

Rear: IP52 (in Nominal position) 

 
Reverse polarity protection  yes, 1 minute 
 

No reverse polarity protection for the Set button inputs (Pin 3 and Pin 5) 

 
Over voltage protection 

12V System  

16 Volt DC for 2h at 60°C 

 

24V System 

32 Volt DC for 2h at 60°C 

 
 