VDO
–
A
Trademark
of
the
Continental
Corporation
09/2008
| A2C59512780
| W
e
reserve
the
right
to
make
changes
in
availability
as
well
as
technical
changes
without
prior
notice.
Continental Trading GmbH | Heinrich-Hertz-Strasse 45 | 78052 Villingen-Schwenningen | Germany
E-mail: [email protected] | www.vdo.com
Sender Unit
2159-0x
Technical Information
Output
Double pulse (inverted)
Imp./revolution
8 (n and v)
Impulse ratio
30-70% ... 70-30%
Operating voltage
6,5 ... 16 V
Power consumption (~U)
max. 15 mA
Operating temperature
-30°C ... +125°C
Storage temperature
-40°C ... +140°C
Connection
unearthed
Output resistor (pull up)
open collector
Protective resistance
1,5 k
Ω
Signal shape
rectangular
Frequency (max.)
< 1 kHz
Output signal A1
U
L
< 1,9 V (1mA)
Output signal A2
inversion of A1
Interference protection
depending on
additional circuit
Radiated susceptibility
DIN 40839 T4 (100V/m)
Outputs, short-circuit proof
30 V, 1 min.
Protection
IEC 529, IP 66
Resistance to vibrations
10 g
Connection of sender unit
to sender unit cable
via bayonet joint
Connection of sender unit to a via thread M22 x 1,5
speedometer drive shaft
or 7/8˝ 18 UNS 2B
Torquet (wrench size)
50 ± 10 Nm (WS 27)
Weight
approx. 120 g
Dimensions (Ø x L in mm)
approx. 39,5 x 65
Threads: