Technical data
Measuring principle:
Utrasonic running-time mesurement
Application range:
0.5 to 120 m depending on ground
and installation conditions
Frequency:
200 kHz
Supply voltage:
10.8 V ... 32 V DC
Current consumption:
Display unit:
about 90 mA at 12 V DC
without illumination, about 250 mA with
illumination
Echo sounder: about 50 mA at 12 V DC
Transmitter power:
about 40 Wrms, about 320 Wpp
Operating temperature:
-10 °C to +60 °C
Type of protection:
DIN 40050 - IP 65 at front, IEC 529
EMC protection:
CE: EN 50081-1, EN 50082-1
Dimensions:
Indicating instrument:
Front ring diameter
105 mm
Installation diameter
86 mm
Installation depth
56 mm (union nut)
Installation depth
90 mm (bracket)
Sounder / Hull sleeve:
Installation diameter:
53 mm
Maximum hull thickness:
36 mm
For internal installation:
Maximum hull thickness:
12 mm
Technical modifications reserved
47
DATA
echo_e.qxd 16.04.1998 08:23 Seite 23
Summary of Contents for DEPTH SOUNDER