Configuring the CTC II
An overview of the “Service” menu parameters
24
• Edition 01/2
009
An overview of the “Service” menu parameters
Program
Range of values
Remark
Version
Standard/ Belgium/ France/
Italy/ Portugal
Distance roller
on/ off
Switching on/ off the function for (check on
roller distance travelled).
When the setting is at
off
the
Distance
parameter cannot be set.
Distance
100 … 10000 m
Entering the test distance for the distance check
on the roller
Default value: 1000 m
Settings road
Length measuring track
10 … 1000 m
Entering the length of the measured track
Default value: 20 m
Setting roller
Test stand type
Double roller/ Brake tester/
Brake double
Setting the test stand type
Double roller
(rolling road test stand)
Both wheels of a drive axle are powered.
The characteristic coefficient imp/ km is
determined from
one
drive axle. The number of
drive axles is not requested.
Brake tester
(Brake test stand)
Only one wheel of the drive axle(s) is powered.
The number of drive axles is requested (number:
1, 2 or 3).
The characteristic coefficient imp/ km is
determined from the powered wheel, doubled
and multiplied by the number of drive axles.
Brake double
(Brake test stand)
Both wheels of a drive axle are powered.
The number of drive axles is requested (number:
1, 2 or 3).
The characteristic coefficient imp/ km is
determined from the powered wheel and
multiplied by the number of drive axles.