1.3 Sensors
1.3.4
Fuel Level Sensor (Lever Type Sensor/Tubular Type Sensor)
❒
An installation opening remaining to be made in the tank at a suitable point for supply level measurement or at an in-
stallation flange or installation opening already provided by the tank manufacturer.
❒
If an installation opening must be made, the tank must be completely drained first. Fill the fuel into an approved contai-
ner.
❒
Risk of explosion exists due to presence of residual gases in the tank! Make sure that the tank is aired
sufficiently (approx. 10 minutes).
❒
Make a preliminary hole in the installation opening using a drill and then finish the hole using a compass saw or piercing
saw. Comply with the safety instructions of the tool manufacturer. Clean the tank of residue from the drilling or sawing
work.
❒
The safety instructions given by the welding equipment manufacturer and the working regulations applying to welding
work must be respected when welding the tank flange.
1. Safety Instructions
Product Manual
Technische Änderungen vorbehalten Technical details subject to change
1 - 8
TU00-0736-0000002
0609