No.
Description
Range
Per
Unit
Default
51
52
53
54
55
56
0 = None
1 = Room temperature (absolute)
2 = Channel temperature (absolute) (room temperature if P02 = 0)
3 = Lowest sensor temperature
4 = Highest sensor temperature
5 = Average sensor temperature
6 = Control temperature
7 = Control temperature relative to control setpoint
Minimum alarm detection during
0 = Spraying
1 = Drying
2 = Both modes
(always detection for single setpoint)
Minimum alarm temperature
Switch differential for minimum alarm
Time delay for minimum alarm
Action at minimum alarm
(message with code and alarm relay function always appear in display)
0 = None
1 = Disable all burner control
Reset minimum alarm automatically
(0 = no, 1 = yes)
0 2
-350 +350
0.1 15
0 99
0 1
0 1
-
1
0.1
1
-
-
-
C
C
min
-
-
2
-50
0.1
0
0
0
60
61
62
63
64
65
66
Maximum alarm detection on
0 = None
1 = Room temperature (absolute)
2 = Channel temperature (absolute) (room temperature if P02 = 0)
3 = Lowest sensor temperature
4 = Highest sensor temperature
5 = Average sensor temperature
6 = Control temperature
7 = Control temperature relative to control setpoint
Maximum alarm detection during
0 = Spraying
1 = Drying
2 = Both modes
(always detection for single setpoint)
Maximum alarm temperature
Switch differential for maximum alarm
Time delay for maximum alarm
Action at minimum alarm
(message with code and alarm relay function always appear in display)
0 = None
1 = Inhibit all burner control
2 = Inhibit burner high
3 = Inhibit burner high, replace with
>
burner low
=
Reset maximum alarm automatically
(0 = no, 1 = yes)
0 7
0 2
-350 +350
0.1 15
0 99
0 3
0 1
-
-
1
0.1
1
-
-
-
-
C
C
min
-
-
0
2
+300
0.1
0
1
0
70
71
72
73
74
75
Maximum limit on
0 = None
1 = Room temperature (absolute)
2 = Channel temperature (absolute) (room temperature if P02 = 0)
3 = Lowest sensor temperature
4 = Highest sensor temperature
5 = Average sensor temperature
6 = Control temperature
7 = Control temperature relative to control setpoint
Maximum limit during
0 = Spraying
1 = Drying
2 = Both modes
(always limit for single setpoint)
Maximum temperature limit
Switch differential for maximum limit
Time delay for maximum limit
Action at maximum limit
0 = No limit (same as P70 = 0)
1 = Inhibit all burner control
2 = Inhibit burner high
3 = Inhibit burner high, replace with
>
burner low
=
0 7
0 2
-350 +350
0.1 15
0 99
0 3
-
-
1
0.1
1
-
-
-
C
C
min
-
0
2
+300
0.1
0
1