VDC Electronics BatteryMINDer 1500 Instructions Manual Download Page 11

Rev. C-072415 

  Page 11 

P/N VDC1500-10MNL

BatteryMINDer

® 

&

 

Plus with SmarTECHnology

®

   

 

Model 1500 Series

TROUBLESHOOTING

VDC Electronics Technical Support: (800) 379-5579 x6

•  Unit does not have an output unless connected to a battery.  In order to 

test the output using a meter, connect the meter to your battery.  When you 

connect the unit, you will see the voltage rise.

•  If the unit is not in maintenance after 72 hours (solid GREEN), check 

to make sure your battery meets the minimum voltage of 3.0 volts. 

Unit will not operate if battery is below the minimum voltage of 3.0 volts. 

If there is a load on your battery, disconnect it and charge again. 

If the problem persists, your battery may be shorted or too badly sulfated. 

Visit our learning center at BatteryMINDers.com for additional battery 

information.

MAINTAINING MULTIPLE BATTERIES

Batteries should be 

charged

 individually.  To properly 

maintain

 multiple 

batteries they should all be the same type (gel, flooded or AGM) and condition.  

It is OK to mix deep cycle and starter.  

Charge

 each battery individually before 

connecting together.  Never connect batteries at different states of charge.  The 

charged battery will rapidly transfer energy to the discharged battery possibly 

causing catastrophic failure.  Once the batteries are charged, use 18 gauge 

or greater wire to connect the batteries or 

for greatest safety protection and 

ease of use, consider investing in the BatteryMINDer Y-Connector Model 

210AY with SmarTECHnology*.

See diagram on the Page 13 for the most common multiple battery 

configuration.

You must connect multiple batteries of the same voltage, wire them in parallel 

(BatteryMINDer positive to positive A to positive B, BatteryMINDer negative to 

negative A to negative B).  . 

If connecting 2 batteries of half your unit’s voltage (example: 6V batteries on a 

12V unit), wire them in series (BatteryMINDer positive to positive A, negative 

A to positive B, negative B to BatteryMINDer negative).  When wired in series 

they act as one large system at the combined voltage (example: 6V+ 6V = 

12V).  You can connect these systems in a series parallel configuration in 

order to charge or maintain 4 or batteries in groups of 2.

*BatteryMINDer

®

 has developed a simple, safe and inexpensive method of connecting multiple 

batteries they call SmarTECHnology

®

-Y.  Using their single SmarTECHnology-Y connector, 

two batteries can be maintained simultaneously using just a single output charger designed to 

maintain batteries.  Adding additional Y-connectors allows from four (4) to eight (8) batteries to be 

connected depending on the maintenance charger capability.   

Summary of Contents for BatteryMINDer 1500

Page 1: ...minal Assembly with 15A replaceable fuse 1510 only CAUTION NOT FOR USE WITH AVIATION BATTERIES NOT FOR USE WITH LITHIUM TYPE BATTERIES POTENTIAL FOR EXPLOSION MAY EXIST IF USED VDC Electronics Inc 155...

Page 2: ...RUCTIONS 9 SPECIFICATIONS 9 CHARGING STATUS 9 SPECIFICATIONS 9 CHARGING STAGES 10 ADDITIONAL FEATURES 10 VOLTAGE TABLE 10 12 V PARALLEL CONNECTION DIAGRAM 10 12 V SERIES PARALLEL USING 6 V BATTERIES 1...

Page 3: ...sed unless absolutely necessary Use of improper extension cord could result in a risk of fire and electric shock If an extension cord must be used make sure a That pins on plug of extension cord are t...

Page 4: ...OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published...

Page 5: ...vehicle to charge always remove grounded terminal from battery first Make sure all accessories in the vehicle are off so as not to cause an arc b Be sure area around battery is well ventilated while b...

Page 6: ...n cause injury to persons c Check polarity of battery posts POSITIVE POS P battery post usually has larger diameter than NEGATIVE NEG N post d Determine which post of battery is grounded connected to...

Page 7: ...st usually has a larger diameter than NEGATIVE NEG N post b Attach at least a 24 inch long 18 gauge AWG insulated battery cable to NEGATIVE NEG N battery post c Connect POSITIVE RED charger clip to PO...

Page 8: ...OFF 4 AC Power connected battery initial condition detected for 3 sec initial battery 10 5V ON OFF OFF 5 AC Power connected soft start charging bulk charging and absorption charging ON FLASH FLASH 6...

Page 9: ...r 4 Charging will be GREEN flashing see item 5 in Table 2 Reverse leads if you do not see this TABLE 3 BatteryMINDer 1500 BatteryMINDer Plus 1510 CHARGING STATUS Power 100 240 VAC Power Connected Batt...

Page 10: ...eps battery at full charge while continually desulfating it ensuring full capacity for the longest possible life ADDITIONAL FEATURES Desulfation is the removal of sulfate build up from your battery s...

Page 11: ...harged battery possibly causing catastrophic failure Once the batteries are charged use 18 gauge or greater wire to connect the batteries or for greatest safety protection and ease of use consider inv...

Page 12: ...sor 4 Temperature Sensor input connector 5 Output cord with quick connect plug 6A Standard Battery Clip cord set with quick connector Shown connected to output cord Model 1500 6B Fully Insulated Batte...

Page 13: ...age Soft Start Float Charging 0 35A 13 4V 25 18 hours timer 10 minutes Charging current 0 Time 100 hours timer limited 5 hours timer limited g n i g r a h C n o i t p r o s b A g n i g r a h C k l u B...

Page 14: ...rt15 Input Output insulation test 1240Vac 60Hz 5mAac no breakdown Cooling By natural cooling Electrical Cable Physical Parameters Input socket UL 2 PIN wall mount Output 1 10 feet 18AWG X2 105 C with...

Page 15: ...DC Electronics In the event that you believe your product may be defective you MUST speak to a VDC Electronics technician at 1 800 379 5579 x6 ET before proceeding further NOTES MODEL BatteryMINDer 15...

Page 16: ...l purchase price including all taxes shipping or handling cost applicable to the purchase Unit must be returned freight prepaid together with Proof of Purchase directly to VDC Electronics Inc NOT TO T...

Reviews: