background image

 

 

VCom Inc. 

TR700B Manual; ml_tr700B_02 (March 2004) 

Approved: C.H. 

 !

"

TRANSMITTER SPECIFICATIONS 

IF Input Frequency   

36-42 MHz (TR700B) 

 

 

 

44.375-50.375 MHz (TR700B-IF1) 

RF Output Frequency 

710-716 MHz 

Linear Output Power +24 dBm at RF port 

Output P1dB   

 

+27 dBm at RF port 

Spectral Mask   

 

FCC CFR 47 Part 27.53 

Gain 

 

 

20 ± 2 dB at 23°C 

Gain Flatness (Frequency Response) 

± 1.0 dB over 710-716 MHz 

Gain Stability over Temperature 

± 2.0 dB over -30 to +60°C ambient 

Phase Noise   

 

-87 dBc/Hz @ 10 kHz 

Spectral inversion   

No spectral inversion 

IF Level for RF Activation 

-45 dBm maximum 

RF Activation/Mute Response Time 

<2 microseconds  

RECEIVER SPECIFICATIONS 

Frequency 

 

 

740-746 MHz  

Gain 

 

 

24 ± 2 dB at 23°C 

Gain Flatness (Frequency Response) 

± 1.0 dB over 740-746 MHz 

Noise Figure   

 

<5 dB typical, 6.0 dB maximum

 

Transmit-Receive Isolation 

88 dB (see IF port spurious specification below)  

GENERAL 

Frequency Stability   

± 20 kHz (-30 to +60°C) 

Frequency Stability over time 

< ±30 kHz over 10 years 

RF Connector   

 

F female, 75 ohms 

IF Connector   

 

F female, 75 ohms 

Input/Output VSWR  

2:1 

DC Supply 

 

 

+18 to 28 V, (+24V nominal), +10W 

Operating Ambient Temperature 

-30 to +60°C 

Size 

 

 

6" x 8" x 0.9" (15.24 x 20.32 x 2.29 cm) 

Mounting 

 

 

Pole mount, 1” to 1.75” diameter pole  

 

RF PORT SPECIFICATIONS 

RF Return Loss 

 

Better than 9 dB in transmit and receive RF bands 

RF Spurious Emissions 

FCC CFR 47 Part 27 

 

 

 

 

IF PORT SPECIFICATIONS 

IF Return Loss  

 

Better than 10 dB over transmit and receive IF bands 

IF Spurious Emissions 

 -50 dBm from 100-860 MHz except 740-746 MHz 

 

 

 

 -85 dBm, 740-746 MHz 

 
Specifications subject to change without notice. 

Summary of Contents for TR700B

Page 1: ...UHF Transceiver TR700B INSTALLATION AND OPERATION GUIDE FOR SYSTEM OPERATORS...

Page 2: ...cation and to make changes in content from time to time without obligation on the part of VCom Inc to provide notification of such revision or change VCom Inc provides this guide without warranty of a...

Page 3: ...factures Agile CATV Modulators 256 QAM Upconverters Digital Video Modulators Frequency Translators Spread Spectrum Devices Off Air Demodulators Video On Demand Products Wireless Cable MMDS Wireless Ca...

Page 4: ...meters is required between this antenna and all persons LES PR CAUTIONS DE S CURIT 1 Avant d installer ou d op rer cet quipement lisez toutes les sections de s curit s d installations et d op rations...

Page 5: ...ing the Unit 8 2 2 Mounting the Unit 8 2 2 1 Mounting the TR700B 8 2 2 2 Mounting the Antenna 9 2 3 Connection to the Antenna 9 2 4 Connection to the Power Inserter and Cable Modem 11 2 5 Waterproofin...

Page 6: ...andard RG 59 cable A single RF connector on the weatherproofed enclosure provides the interface to the transmit receive antenna for rapid setup The Transceiver is configured to work with standard cabl...

Page 7: ...Flatness Frequency Response 1 0 dB over 740 746 MHz Noise Figure 5 dB typical 6 0 dB maximum Transmit Receive Isolation 88 dB see IF port spurious specification below GENERAL Frequency Stability 20 k...

Page 8: ...ing hardware is included in the box for mounting the TR700B to the pole 1 pole catch 1 V bolt 2 x20 flange locknuts for connecting V bolt and pole catch to the pole The TR700B was designed for mountin...

Page 9: ...ype Antenna Gain Watts dBm dBi 0 25 24 Yagi 10 dBi 0 25 24 Flat planar array 9 dBi 0 25 24 Window mount planar array 7 dBi Included with the TR700B unit is a self adhesive label for application to the...

Page 10: ...VCom Inc TR700B Manual ml_tr700B_02 March 2004 Approved C H 10 Connect the TR700B to the Antenna via the N Connector DIAGRAM 2 3A CONNECTION TO THE ANTENNA...

Page 11: ...gned The power inserter has three connections DC POWER Connect to wall adapter with RG 59 cable with F connectors TO MODEM Connect to cable modem install modem only after the antenna is aligned TO TRA...

Page 12: ...the N connector but the F connector also should be sealed using the same technique STEP 1 Use one 6 section of rubber sealing tape Starting at the TR700B end stretch the tape and wrap it around the c...

Page 13: ...m Inc TR700B Manual ml_tr700B_02 March 2004 Approved C H 13 STEP 3 When done the connection should be tightly wrapped with tape with a good seal to the cable DIAGRAM 2 5C WATERPROOFING CONNECTION STEP...

Page 14: ...is available Monday to Friday from 8 30 a m to 4 30 p m CST statutory holidays excepted To obtain an R M A number you may Call 306 955 7075 press 0 for Operator or 3 for Service Dept Fax 306 384 0086...

Page 15: ...ult is found the item is subject to the current Test Fee and will be exempt from warranty 5 Any product exhibiting external damage either from shipping improper handling or use will be subject to insp...

Page 16: ......

Page 17: ...150 Cardinal Place Saskatoon Saskatchewan S7L 6H7 Canada Tel 306 955 7075 Fax 306 955 9919 www vcom com sales vcom com...