Vacuum Packaging Machine VC999 K7
Error display and troubleshooting
2008-11-26
Art.-No. 592.016
Page 75/121
No Alarm
messages
Cause
Remedy
23 PLC battery voltage too low
This message appears if the charge
state of the PLC buffer battery is too
low.
The battery should be replaced as
quickly as possible, and be re-
moved and installed within 20
seconds. If necessary, contact the
VC999 Customer Service Depart-
ment!
Temperature control device may be
switched off
Make sure the temperature control
device is switched on
El. supply of the temperature control
device may be interrupted
Check el. supply of the tempera-
ture control device
24 Set temperature sealing bars
not reached
Calibrate sealing bars
25 Temperature monitoring of
pumps has triggered
Overheating of the vacuum pump
Allow pump to cool down.
Carry out possible pump service
Input value of the set temperature is
less than the actual temperature
Check the input value of the set
temperature
26 Actual temp. sealing bars is
higher than set point
Error in the temperature control circuit
Carry out calibration
Incorrect thermal relay setting
Check thermal relay setting
27 El. supply of the rotary blade
interrupted
Rotary blade motor overheated
Allow motor to cool down
Mechanical movements hindered
Check mechanical movement
Limit switch defective
Replace limit switch
28 Machine is not in initial posi-
tion
El. supply line to the limit switch or
valve defective
Consult VC999 Customer Service
Department
29 Cooling temperature not
reached
Error in the temperature control circuit
Re-calibrate
Burn-in sealing bars
Check input value
Change input value
30 Ventilation set point not
reached
Air flow interrupted
Check for soiling
Conveyor belt motor drive overheated
Check thermal relay setting
Conveyor belt motor drive defective
Consult VC999 Customer Service
Department
Motor drive overheated
Allow motor drive to cool down
31 Temp. monitoring motor con-
veyor belt has triggered
Conveyor belt tension too high
Correct belt tension
32 Communication PLC - fre-
quency converter faulty
El. connection PLC – FC incorrect
Check el. supply of FC
Check bus CPU – FC
Incorrect calibration
Calibrate vacuum system
Clean or replace vacuum sesnor
33 Measuring system: vacuum
value faulty
Vacuum sensor defective or soiled
Check el. supply of vacuum sensor
34 Error reset safety module
Emergency Stop
EMERGENCY STOP active
At least 1 EMERGENCY STOP circuit
interrupted
Release EMERGENCY STOP
35 Emergency Stop circuit is
interrupted
EMERGENCY STOP active
At least 1 EMERGENCY STOP circuit
interrupted
Release EMERGENCY STOP
Consult VC999 Customer Service
Department
36 Safety monitoring sealing
system is defective
Safety contactor sealing system defec-
tive
Replace contactor
37 Vacuum system cannot be
calibrated
Vacuum sensor defective or soiled
Clean or replace vacuum sesnor
Check el. supply
38 Intermediate ventilation can-
not be carried out
Ventilation valve does not open
Check valve for soiling
Summary of Contents for K7
Page 2: ......
Page 4: ......
Page 44: ...Vacuum Packaging Machine VC999 K7 Operation Page 44 121 Art No 592 016 2008 11 26 Fig 9 7...
Page 101: ...Vacuum Packaging Machine VC999 K7 Appendix 2008 11 26 Art No 592 016 Page 101 121...
Page 102: ...Vacuum Packaging Machine VC999 K7 Appendix Page 102 121 Art No 592 016 2008 11 26...
Page 103: ...Vacuum Packaging Machine VC999 K7 Appendix 2008 11 26 Art No 592 016 Page 103 121...
Page 104: ...Vacuum Packaging Machine VC999 K7 Appendix Page 104 121 Art No 592 016 2008 11 26...
Page 105: ...Vacuum Packaging Machine VC999 K7 Appendix 2008 11 26 Art No 592 016 Page 105 121...
Page 106: ...Vacuum Packaging Machine VC999 K7 Appendix Page 106 121 Art No 592 016 2008 11 26...
Page 107: ...Vacuum Packaging Machine VC999 K7 Appendix 2008 11 26 Art No 592 016 Page 107 121...
Page 108: ...Vacuum Packaging Machine VC999 K7 Appendix Page 108 121 Art No 592 016 2008 11 26...
Page 109: ...Vacuum Packaging Machine VC999 K7 Appendix 2008 11 26 Art No 592 016 Page 109 121...
Page 110: ...Vacuum Packaging Machine VC999 K7 Appendix Page 110 121 Art No 592 016 2008 11 26...
Page 111: ...Vacuum Packaging Machine VC999 K7 Appendix 2008 11 26 Art No 592 016 Page 111 121...
Page 112: ...Vacuum Packaging Machine VC999 K7 Appendix Page 112 121 Art No 592 016 2008 11 26...
Page 113: ...Vacuum Packaging Machine VC999 K7 Appendix 2008 11 26 Art No 592 016 Page 113 121...
Page 114: ...Vacuum Packaging Machine VC999 K7 Appendix Page 114 121 Art No 592 016 2008 11 26...
Page 115: ...Vacuum Packaging Machine VC999 K7 Appendix 2008 11 26 Art No 592 016 Page 115 121...
Page 116: ...Vacuum Packaging Machine VC999 K7 Appendix Page 116 121 Art No 592 016 2008 11 26...
Page 117: ...Vacuum Packaging Machine VC999 K7 Appendix 2008 11 26 Art No 592 016 Page 117 121...
Page 118: ...Vacuum Packaging Machine VC999 K7 Appendix Page 118 121 Art No 592 016 2008 11 26...