Command Line Interface
H.264 Encoding/Decoding Appliance Getting Started Guide
51
Example 2
This example shows how to set the unicast
Destination IP Address
and enable the transmitter
for Program1 and Transmitter1.
VBrick# svar vbrickProgramTransmitterInetAddrType.1=1
VBrick# svar vbrickProgramTransmitterInetAddr.1=172.22.118.105
VBrick# svar vbrickProgramTransmitterEnable.1=2
VBrick# svar vbrickProgramTransmitterApplySet.1=2
Scripting Syntax
•
Script commands must start in column 1.
•
svar
(set variable) must precede the variable name.
•
Wait time is defined milliseconds. A value of 1000 = 1 second.
•
Most variable changes require an
ApplySet
.
•
There is no clear command.
•
There is no chaining of scripts.
•
Comments are not allowed on the same line as a command.
•
Comments start with
//
in column 1.
•
Blank lines are not allowed.
•
All scripts are executed in a strictly serial manner by a single task.
•
While executing a script it is possible to miss a double change of any event.