Turn on the power at fuse or circuit box.
Turn off the power at fuse or circuit box
Installation Steps
The Position of Control Panel
Step 1: Rotate the sensor lens from left side to right side
to show the adjustable knobs and slide switch.
(See Fig.1)
Step 2: Adjust time
by knobs and choose the mode you want by
slide switch. (See Fig.2 and Fig.A)
Step 3: Restore the sensor lens to original position.
(See Fig.3)
low level brightness and sensitivity
Page 2 / 5
“Time” Knob
“Sens” Knob
Slide Switch
“Low Level” Knob
Time
Low Level Sens
Fig.A
Test 3H 6H
0
1. Attach the crossbar unit (A) to the outlet box by using two mounting screws (B). Adjust the length of the preinstalled
fixture mounting screws if necessary.
Note: Make sure that the fixture mounting screws are lined up horizontally to make the fixture level.
2. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows:
• Connect the hot wire (black insulation) from the fixture to the black wire from the power source.
• Connect the neutral wire (white insulation) from the fixture to the white wire from the power source.
• Attach the fixture ground wire (bare wire) to the crossbar unit (A) with the green ground screw, then depending
on local code, connect it to the house ground wire with the wire connector (C).
Carefully put all of the wires back into the outlet box.
3. Attach the backplate of the fixture to the crossbar unit (A) by inserting fixture mounting screws into open holes on the
backplate, then secure it with two rubber pads (E) and two bolt nuts (D).
Note: With silicone caulk compound, caulk completely around where the backplate meets with the wall
surface to prevent water from seeping into the outlet box.
4. Attach the shade to the socket, then secure it with the socket ring.
5. Install the bulb (not included). Check relamping label at socket area or packaging for maximum wattage allowed.
Sensor
Lens
Fig.1
View Fig.A
Fig.2
Sensor
Lens
Fig.3
230620