Vaxcel T0599 Assembly And Installation Instructions Download Page 2

Page 2 / 5

 

 

 

 

 

 

 

1. Unscrew the two set screws (D), remove the mounting plate unit (A) from the backplate.

     

2. Attach the mounting plate unit (A) to the outlet box by using two mounting screws (B). 

    

Note: Make sure that the two set holes are lined up horizontally to make the fixture level.

3. Take a glass panel and gently slide it into the bottom notch of the frame in place, secure it by pressing the two clips 

    on top side of the frame. Repeat with the other glass panels. (See Fig.1 and Fig.2)

    

4. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows:    

    • Connect the hot wire (black insulation) from the fixture to the black wire from the power source.  

    • Connect the neutral wire (white insulation) from the fixture to the white wire from the power source.  

    • Attach the fixture ground wire (bare wire) to the mounting plate unit (A) with the green ground screw. 

      Then, depending on local code, connect it to the house ground wire with the wire connector (C).  

    Carefully put all of the wires back into the outlet box.

5. Attach the backplate of the fixture to the mounting plate unit (A) by aligning holes, secure the two set screws (D) 

    from the side hole of the backplate into the hole of the mounting plate unit (A). 

    Note: With silicone caulk compound, caulk completely around where the backplate meets with the wall

    surface to prevent water from seeping into the outlet box.

6. Install the bulb (not included). See relamping label at socket area or packaging for maximum wattage allowed.

    

Turn off the power at fuse or circuit box

Turn on the power at fuse or circuit box

Installation Steps

The Position of  Control Panel

 

Step 1: Rotate the sensor lens from left side to right side

             to show the adjustable knobs and slide switch. 

            (See Fig.3) 

Step 2: Adjust time

             by knobs and choose the mode you want by

             slide switch. (See Fig.4 and Fig.A)

Step 3: Restore the sensor lens to original position.

             (See Fig.5) 

 low level brightness and sensitivity

“Time” Knob

“Sens” Knob

Slide Switch

“Low Level” Knob

Time

Low Level Sens

Fig.A

Test 3H 6H

0

230223

Sensor 

Lens

Fig.3

Sensor 

Lens

Fig.5

Fig.4

View Fig.A