Installation Steps
Turn off the power at fuse or circuit box.
Turn on the power at fuse or circuit box.
1. Unscrew the two bolt nuts (D)
,
remove the two rubber pads (E) and the mounting plate unit (A) from the backplate.
2. Attach the mounting plate unit (A) to the outlet box by using two mounting screws (B). Adjust the length of the
preinstalled headless screws if necessary.
Note: Make sure that the headless screws are lined up horizontally to make the fixture level.
3. Install the bulb (not included). See relamping label at socket area or packaging for maximum wattage allowed.
4.
Gently place glass shade into the metal frame, then secure it by pressing the clips from top side. (See Fig.1)
5. Unscrew two bolt nuts-a and two
rubber pad
s-a from set screws, attach the metal frame to the fixture by inserting
set screws, then secure it with two
rubber pad
s-a and two bolt nuts-a.
6. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows:
• Connect the hot wire (usually black insulation) from the fixture to the black wire from the power source.
• Connect the neutral wire (usually white insulation) from the fixture to the white wire from the power source.
• Attach the fixture grounding wire (usually green with the insulation or bare wire) to the mounting plate unit (A)
with green grounding screw. Then, depending on local code, connect it to the house grounding wire with the
wire connector (C).
Carefully put all of the wires back into the outlet box.
7. Attach the backplate of the fixture to the mounting plate unit (A) by inserting headless screws into set holes on
backplate, then secure it with two rubber pads (E) and two bolt nuts (D).
Note: With silicone caulking compound, caulk completely around where the backplate meets with the wall
surface to prevent water from seeping into the outlet box.
Page 2 / 5
The Position of Control Panel
Step 1: Rotate the sensor lens from left side to right side
to show the adjustable knobs and slide switch.
(See Fig.2)
Step 2: Adjust time
by knobs and choose the mode you want by
slide switch. (See Fig.3 and Fig A).
Step 3: Restore the sensor lens to original position.
(See Fig.4)
low level brightness and sensitivity
Sensor
Lens
Fig.2
View Fig.A
Fig.2
Fig.3
Sensor
Lens
Fig.4
“Time” Knob
“Sens” Knob
Slide Switch
“Low Level” Knob
Time
Low Level Sens
Fig.A
Test 3H 6H
0