Customization Options
Shut-off Delay
Fig. 5
Test Off Auto PC
Low Level
(View from back of sensor lens)
Time
Sens
Mode
1. The Shut-off delay is the length of time that the light will stay in
high-level brightness after motion stops.
2. The Shut-off delay can be adjusted by using the “Time” knob when
the slide switch is set in “Off” or “Auto” mode.
3. The range of shut-off delay is 5 seconds to 3 minutes.
4. Rotate the knob clockwise for increasing the shut-off delay.
5. Rotate the knob counterclockwise for decreasing the shut-off delay.
Sensitivity of Motion Sensor
1. The sensitivity can be adjusted from 5 to 40 feet by using the "Sens" knob. (See Fig.5).
2. Turn the knob clockwise for increase sensitivity.
3. Turn the knob counterclockwise for decrease sensitivity.
The following parts are available for reorder if damaged or missing. Call our toll free at 1-800-482-9235.
Where you install your lantern is important:
Be sure the light is mounted straight on the wall;
otherwise, the detection distance may be limited.
5`
6`
10`
40`
Fig.6
Fig. 7
180˚
Motion
Least sensitivity
Most sensitivity
Sensor
Fig. 8
Motion
Assembly Kit
4860MM (1 SET) FOR T0575
4859MM (1 SET) FOR T0576
Spare Parts List:
Set Screw
X2
4860SS For T0575
4859SS For T0576
Glass Panel
X3
10109CS
Finial
X1
4860FF For T0575
4859FF For T0576
Cross Bar Unit
X1
Mounting Screw
X2
Wire Connector
X3
Ball Nut
X2
Rubber Pad
X2
AA
BB
CC
DD
EE
NOTE:
1. The sensitivity of the motion sensor will increase as the
environmental temperature gets colder. For best performance,
gently clean the lens with a soft cloth every 1 or 2 months to
ensure maximum sensitivity.
2. The magnitude of adjustment for sensitivity and time may not be
precisely proportionate to the amount when the knob is turned.
(See Fig.5)
3. When installed at a height of 6.5 feet, at 77 degrees Fahrenheit,
the light will provide a maximum detection distance of 40 feet
and detection range of 180 degrees. (See Fig.6 Fig.7)
4. The sensor will be more sensitive to motion across its
detection path than motion directly towards it. (See Fig.8)
5. To reduce possible nuisances, do not mount the fixture
near a heat source like an air conditioner, vent or furnace
exhaust, or in a direction facing any reflecting object or
other light source.
Page 4 of 5
200313
B
C
A
A: 16-3/4"
B: 6-3/8"
C: 6-3/4"