Installation Steps

1. The fixture mounting bracket is pre-assembled on the light fixture.

    Unscrew the fixture mounting screw in order to remove the mounting 

    bracket.

2. 

 Install the mounting strap to the outlet box with the stamped word 

     “FRONT” facing away from the outlet box, using two mounting 

     screws that best fit the outlet box. Mounting bracket should sit 

     flush against wall surface when secured.(Choose one matching 

     pair of suitable mounting screws from the 3 pairs provided)

3. 

Pull out the source wires from the outlet box. Make wire connections 

    using wire nuts as follows:

     ---Connect the black wire from the fixture to the “hot” wire from the 

         power source. (usually black)

     ---Connect the white wire from the fixture to the neutral wire from the 

         power source. (usually white)

     ---Connect the grounding wire from the fixture to the grounding wire 

         from the power source. (usually green / yellow insulation)

     Carefully tuck the wires back into the outlet box.

4. Place mounting bracket against the outlet box, insert the mounting bracket screw through the mounting bracket hole, 

    thread mounting bracket screw into the center hole of the mounting strap. Tighten the mounting bracket screw securely.

    ▲   When mounting to a wall, the “UP” arrow must point upward. (See Fig. 1)

    ▲   When mounting to an eave, the “UP” arrow must point toward the building. 

5. Attach the back plate of the light fixture to the mounting bracket, secure it with the fixture mounting screw.

6. With silicone caulking compound, caulk completely around where the mounting bracket meets the wall surface. 

    CAUTION: Be sure to caulk completely where the mounting bracket meets the wall surface to prevent water

    from seeping into the outlet box. 

  

 

 

Sensor

Mounting Strap

Mounting Bracket

Outlet Box

Wire Nut

Back Plate

Mounting Screw

Light Head

sensor

 

Adjusting the Sensor Head: 

1. Aim sensor head toward desired detection area, maintaining a

    5° - 40° downward angle to allow moisture to drain.

    Note: Make sure sensor head is positioned with controls facing 

    toward the ground.

2. You can rotate the sensor head up and down to change the coverage

    area. (See Fig. 2) 

Note: Range set too high may increase false triggering.

 (See Fig. 3 and Fig. 4 on Page 3) 

Turn off the power at fuse or circuit box.

Turn on the power at fuse or circuit  box.

Fig. 2

Fixture Mounting Screw

Mounting Bracket Screw

Fig. 1

FRONT