Vax V-091Series Instruction Manual Download Page 7

7

Vax Careline

0870 606 1248

dirt container & filter / clearing blockages

Cleaning the Filter

IMPORTANT: An extra central HEPA filter has
been included in the carton packaging.

Vax

recommends replacing the central HEPA filter every
6-12 months.

Remove the dirt container as directed.

Release the filter safety latch located on top of the dirt

container and pull out the central filter (Fig.6/3).

Gently tap the filter against the side of a rubbish bin to
remove excess dirt.

The central filter can be washed in warm water (max
40°C). Allow to air dry completely before replacing.

NOTE: Do NOT use any detergents or boiling water to
wash the filter. Vax recommends washing the filter
every time you empty the dust container.

Return the central filter to the dirt container ensuring the
filter safety catch has been reset.

Replace the dirt container as directed.

Post-motor Filter

NOTE: This is located on the right hand side of the
vacuum cleaner.

Release the post-motor cover and remove the filter by
pressing in the catch on the left hand side.

Replace the post-motor filter every 9-12 months.

Replace the post-motor filter and cover before re-starting
the vacuum cleaner.

7. Clearing Blockages

WARNING: To reduce the risk of electric shock,
the power cord must be disconnected before

performing maintenance or troubleshooting checks.

Turn the vacuum cleaner off and unplug from the electrical
outlet.

The flexible hose, stretch hose (Model:V-091S only) and
X-tend (Model: V-091X only) can be disconnected from the
vacuum cleaner by pushing in the button on the hose and
pulling away from the machine. Remove any blockages
found then re-connect the hose securely.

Removing debris from the TurboTool

(Model: V-091P,

V-091PB, V-091PBA, V-091S, V-091PA V-091FC only)

Switch the vacuum cleaner off and disconnect the power
plug from the electrical outlet.

Rotate the locking ring 180º (Fig.7/1).

Lift the top cover off and remove any blockage (Fig.7/2).

To re-assemble, ensure that the tabs are engage. Pivot the
lower housing closed and rotate the locking ring 180º
(Fig.7/2).

Fig.6/3

LOCKING RING

Fig.7/1

TABS

Fig.7/2

!

!

Summary of Contents for V-091Series

Page 1: ...Please read carefully before using this cleaner Always fully extend the mains cable before use Retain for future reference Vax careline 0870 6061248 instruction manual Bagless cylinder Vax model numbe...

Page 2: ...n 3 Floor tool parking slot 4 Post motor filter cover 5 Wheel 6 Cord rewind button 7 Variable power dial 8 Power level indicator 9 Carry handle 10 Quick release dirt container button located under saf...

Page 3: ...Central HEPA filter Additional TurboBrush Model V 091TB V 091X only Accessories Fig 1 2 Fig 1 3 Fig 1 4 Fig 1 5 Hard Floor Tool V 091P V 091PB V 091PBA only TurboTool V 091P V 091PB V 091PBA V 091S V...

Page 4: ...parts 12 Do not pick up hot coals cigarette butts matches or any hot smoking or burning objects 13 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the pr...

Page 5: ...tch on the combination floor head to raise the brushes Model V 091TB V 091X V 091P V 091PB V 091PBA only Attach the TurboBrush floor head to the end of the extension tube For large carpeted areas only...

Page 6: ...ir cleaning 1 The hose fits directly into the hose inlet on the vacuum cleaner 2 The handle fits directly on to the telescopic extension tube 3 To release the extra length hose press the release clips...

Page 7: ...ase the post motor cover and remove the filter by pressing in the catch on the left hand side Replace the post motor filter every 9 12 months Replace the post motor filter and cover before re starting...

Page 8: ...t the power plug from the electrical outlet Lay the TurboBrush floor head on a flat surface and turn over to expose the brushbar Using a pair of scissors cut through any threads or hairs caught by the...

Page 9: ...operly Solution Review dirt container replacement Cause Dirt container full or blocked Solution Empty dirt container Cause Clogged filters Solution Remove clean and replace filters PROBLEM Accessories...

Page 10: ...and model number of the carpet cleaner before calling There are over 400 approved Vax Service Agents in the UK For the nearest Service Agent please call the Vax Careline www vax co uk 11 Technical Spe...

Page 11: ...11 Vax Careline 0870 606 1248 This page has been left intentionally blank...

Page 12: ...Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where...

Reviews: