background image

3

Vax Careline

0844 412 8455

safety information

2. Safety Information

For Household Use Only

When using the vacuum cleaner, basic safety precautions
should always be observed, including the following:

1.

Only use the vacuum cleaner indoors on dry
surfaces.

2.

Turn off the vacuum cleaner controls before
connecting or disconnecting from the mains supply.

3.

Always unplug the vacuum cleaner before
connecting or disconnecting the vacuum hose and
accessories.

4.

Close attention is necessary when used by or near
children. Do not allow children to use as
a toy.

5.

Use only as described in this manual.
Use only the manufacturer’s recommended
attachments.

6.

Do not use the vacuum cleaner if it has been
dropped, damaged, left outdoors or dropped into
water. Do not use the vacuum cleaner with a
damaged cord or plug. If the supply cord or plug is
damaged, return the vacuum cleaner to a Vax
Authorised Service Agent or suitably qualified
person for examination, repair or adjustment.

7.

Do not pull or carry by the cord. Do not use the cord
as a handle, close a door on the cord or pull the cord
around sharp edges or corners. Do not run the
vacuum cleaner over the cord. Keep the cord away
from heated surfaces.

8.

Do not handle the plug or vacuum cleaner with wet
hands. Do not use outdoors or on wet surfaces.

9.

Do not put any objects into openings. Do not use
with any openings blocked and do not restrict air
flow. Keep all openings free of dust, lint, hair or
anything that may reduce airflow.

10. Keep hair, loose clothing, fingers and all parts of the

body away from openings and moving parts.

11. Do not pick up hot coals, cigarette butts, matches or

any hot, smoking or burning objects.

12. Do not pick up flammable or combustible materials

(lighter fluid, petrol, kerosene, etc) or use in the
presence of explosive liquids or vapours.

13. Do not vacuum up harmful or toxic material (chlorine

bleach, ammonia, drain cleaner, etc).

14. Do not vacuum up hard or sharp objects such as

glass, nails, screws, coins, etc.

15. Do not use without the filters in place.

16. Take extra care when vacuuming on stairs.

17. Keep vacuuming area well lit.

18. Store the vacuum cleaner indoors in a cool, dry area.

19. Turn off the on/off switch before unplugging the

vacuum cleaner.

20. Use only CE-approved 13 amp extension cords. Non-

approved extension cords may overheat. Care should
be taken to arrange the cord so that the cord cannot
be pulled or tripped over.

WARNING:

Always switch off and unplug the

vacuum cleaner from the electrical outlet

before assembling, opening or emptying the dirt
container, or before connecting/disconnecting the
attachments.

CAUTION:

The vacuum cleaner is a very powerful

unit. Before plugging the cord into the electrical

outlet, make sure the switch is in the ‘off’ position. Hold
the vacuum cleaner firmly when starting and in use.

IMPORTANT:

If the inlet, hose or extension tube is

blocked, switch off the vacuum cleaner and

remove the blockage(s) before re-starting the vacuum
cleaner.

IMPORTANT:

Cleaning filters regularly improves

vacuum performance. Make sure all filters are

replaced back into the vacuum cleaner before using. This
vacuum cleaner is intended for household use only and
not for commercial or industrial use.

PLEASE KEEP THESE INSTRUCTIONS FOR
FURTHER USE.

!

!

!

!

Motor Thermostat

IMPORTANT:

The motor is equipped with a

thermal cut-out. If for any reason, the vacuum

cleaner should over-heat, the thermostat will
automatically turn the unit off. Should this occur,
unplug the vacuum cleaner from the electrical outlet
and turn off the switch. Remove the dirt container
and empty. Clean the filters. Allow the cleaner to cool
for approximately one (1) hour. To re-start, plug into
an electrical outlet and switch back on.

!

U90-MVX-P Mach VX Pet User Guide.qxd:v1  21/12/09  17:38  Page 3

All manuals and user guides at all-guides.com

Summary of Contents for U90-MVX-P

Page 1: ... when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brush bar when using this cleaner on lino and hard flooring Vax cannot be held responsible for damage to these surfaces if the customer fails to take notice of this recommendation U90 MVX P Mach VX Pet User Guide qxd v1 21 12 ...

Page 2: ... Handle Extension Wand Release Button 22 Upper Hose 23 Dusting Brush Upholstery Tool 24 Power Cord 25 Lower Hose 26 Wheels Fig 1 1 2 3 8 9 10 11 12 13 14 5 6 20 21 22 23 24 25 26 15 16 17 18 19 4 7 U90 MVX P WARNING This cleaner has a constantly rotating brush bar which when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax ...

Page 3: ... or vapours 13 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 14 Do not vacuum up hard or sharp objects such as glass nails screws coins etc 15 Do not use without the filters in place 16 Take extra care when vacuuming on stairs 17 Keep vacuuming area well lit 18 Store the vacuum cleaner indoors in a cool dry area 19 Turn off the on off switch before unplugging...

Page 4: ...push the handle release pedal located on the lower left side of the cleaner CAUTION Brushbar continues to rotate while hose is removed or in use and at all times while cleaner is on Keep hair loose clothing fingers and all parts of body away from brush area while cleaner is on Cleaner must be in the upright position to lift the rotating brush off the carpet when cleaning above the floor Fig 3 1 BA...

Page 5: ...mply snap off the square plastice ring housing the bristles To return to dusting brush for delicate surfaces and stowable form simple push the ring back into place until you feel a snap Extension Wand Lift wand cap to attach hose to handle extension wand Fig 4 9 Choose any of the handy accessories or use the extension wand alone Fig 4 10 Simply push the attachment firmly onto the end of the extens...

Page 6: ...ve Clean foam filter Separate the filter assembly by removing the foam filter from its plastic housing Tap the foam filter on the inside of a rubbish bin to remove excess dust and dirt from filter Wash foam filter Hold foam filter under running water to wash Ring excess water out of filter Allow filter to dry for at least 24 hours before replacing in filter cartridge Replace foam filter Return foa...

Page 7: ...ace exhaust filter Return exhaust filter to base of cleaner and snap into place Replace exhaust filter cover and snap into place to secure Replace dirt container Return dirt container to cleaner Align slot on bottom of dirt container with tab on cleaner Push to snap into place REGULAR MAINTENANCE Each time the dirt container is emptied the foam filter should be checked and when necessary cleaned F...

Page 8: ...ion of screws Flip cleaner right side up Rotate nozzle guard forward and lift off Lift and remove brushbar Dispose of old belt To replace belt or brushbar Slide belt onto motorshaft Place new belt in area of brushbar without bristles With new belt in place pull and slide brushbar into nozzle making sure that the brushbar end caps are in the correct orientation Fig 6 5 inset Rotate brushbar manuall...

Page 9: ... Flathead screwdriver gently pop open the lens Remove lens Fig 7 1 Pull bulb out of socket Do NOT twist Gently push bulb into socket to replace Replace lens by aligning tab and snapping into place Re attach nozzle guard by aligning the four 4 tabs in the base slots Rotate nozzle guard back in place Fig 6 7 Replace all three 3 screws to secure nozzle guard Fig 6 7 Fig 6 8 Fig 7 1 Fig 7 2 Fig 7 3 U9...

Page 10: ...rt container Pg 6 and check dirt container inlet located on cleaner Fig 8 1 3 Remove nozzle guard see Fig 8 2 by removing the three 3 screws Remove obstructions Refer to Page 8 for belt and brushbar removal and replacement WARNING To reduce the risk of injury from moving parts unplug before servicing Clearing Blockages from the TurboTool 1 Turn the TurboTool over and slide off the O ring Fig 8 1 2...

Page 11: ...e Dirty filters or filter container Solution Clean change filters or filter container PROBLEM Accessories won t pick up Cause Accessories not attached correctly Solution Refer to page 5 for fitting information PROBLEM Brushbar does not turn Cause Brushbar blocked Solution Remove blockages PROBLEM Air flow restricted with attachment use Cause Attachment use restricts air flow Solution Check attachm...

Page 12: ... 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website vax co uk U90 MVX P Mach VX Pet User Guide qxd v1 21 12 09 17 38 Pag...

Reviews: