6. Battery Removal & Disposal 

The cordless hand/stick vacuum is powered 

by Nickel-Cadmium (Ni-Cd) batteries, which 

must be recycled or disposed  in accordance 

with  local  requirements.  The  battery  pack 

used  in  this  model  is  replaceable,  however 

care should be taken when doing so. Follow 

these steps when replacement is required:
1.  Remove  the  dust  container  by  pressing 

the dust cup release button.

2.  Turn the handheld on its side with the four 

screws facing towards you.

3.  Using a phillips head screwdriver, remove 

all  four  screws  and  separate  the  two 

halves of the motor cover.

4.  The  battery  is  now  accessible,  and  is 

comprised  of  two  parts,  linked  together 

by  a  connecting  wire.  Be  careful  not  to 

move any other components.

5.  Disconnect the two battery clips from the 

battery terminals.

6.  Remove  the  battery  assembly  from  its 

locating compartment.

7.  Fit  the  new  battery  into  the  battery 

compartment.

8.  Reconnect the battery clips to the battery 

terminal.

9.  Replace the outer cover and ensure that 

the two cover halves fit together properly.

10. Screw in the four screws removed earlier.

11. Charge the battery for a minimum of 20 

hours before use.

 

Call  your  nearest  recycling  centre 

or  local  authority  for  information  on 

the  recycling  and  disposal  of  Ni-Cd 

batteries. Do NOT 

replace the batteries 

used in this product with any other type of 

battery.

CAUTION: 

•  Use  only  with  the  battery  pack  supplied 

with the unit.

•  Do not attempt to remove the battery pack 

from the unit to charge it.

•  Never throw the battery pack or unit into a 

fire or incinerate.

•  Do not attempt to remove or damage the 

battery casing.

•  Battery  must  be  recycled  or  disposed  of 

properly at the end of its service life.

7. Technical Specifications

Model Name: 

Spirit

Model Number: 

VR-380

Part Number: 

55000

Charger Supply Voltage:  220-240V/50Hz

Battery: 

14.4 V Ni-Cd

Dust Capacity: 

600ml

Filter: 

Cage and Filter

Weight: 

3kg

Subject to technical change without notice

VAXCARE Service & Help

AUSTRALIA 1300 36 4040

NEW ZEALAND 0800 800 900

If you have any queries or concerns about 

using your Vax, call VAXCARE. 

Please  make  a  note  of  the  serial  number 

and  model  number  of  the  appliance  before 

calling. 

(Aust only: Mon-Fri. 10.00am to 6.00pm. EST)

Calls are charged at the local rate.

An answerphone is available outside of these 

hours. 
There  are  over  300  approved  Vax  Service 

Agents in Australia and New Zealand. For the 

nearest Service Agent, please call VAXCARE 

or visit www.vax.com.au

6

2.Assembly

NOTE:

 Ensure that the unit is not connected 

to the charger before assembling the handle.
1.  Align 

the 

t e l e s c o p i c 

tube  on  the 

handle 

with 

the  opening 

on  the  power 

unit  housing 

(Fig/2.1).

2.  Slide 

the 

telescopic tube into the opening until it is 

seated firmly into position.

3.  Push  on  the  telescopic  handle  release 

button to adjust the height of the handle.

3. Charging Your

    Vacuum Cleaner

Before using the vacuum, charge the vacuum 

cleaner for a minimum of 20 hours.

NOTE:  Ensure  that  the  On/Off  switch 

on  the  hand  vac  is  in  the  “Off”  position 

before charging.
NOTE:

  The  power  unit/hand  vac  does 

not  have  to  be  in  the  power  unit/hand  vac 

receptacle to charge the battery.

1.  Place the vacuum near an electrical power 

outlet  (220-240V/50Hz)  and  plug  in  the 

charger.

2.  Connect 

the 

charger  to  the 

charging 

jack 

(Fig/3.1). 

  The red charging 

indicator light will 

illuminate  when 

the 

vacuum 

cleaner  is  being 

charged.

3.  The vacuum cleaner will run for maximum 

operational  time  only  if  it  has  been  fully 

charged. The normal full charging time for 

this  vacuum  is  20  hours.  To  fully  charge 

the  unit,  run  the  vacuum  cleaner  until  it 

stops, then fully recharge the battery.

NOTE:

  Peak  performance  may  only  be 

attained after the unit has been charged and 

discharged two (2) or three (3) times.

To Maximize the Life of your Ni-Cd 

Batteries

1.  Charge for a minimum of 20 hours before 

initial use. Failure to do so will significantly 

reduce the battery life.

2. 

Do not store the unit with the charging 

adaptor attached and plugged in.

3.  Only recharge when the batteries are fully 

discharged (or as close to fully discharged 

as possible).

4.  Do not store in areas of high temperature 

or humidity.

5. 

NOTE:

  Fully  discharge,  then  completely 

re-charge the unit at least once a month.

6.  After  three  (3)  months  of  storage,  the 

appliance  should  be  fully  discharged 

and  then  recharged  to  maximize  battery 

power.

7.  Only  use  the  charger  supplied.  If  other 

chargers are used, damage to the battery, 

appliance  or  personal  property  could  be 

caused. 

8.  Ni-Cd batteries have a long useful life but at 

some time they will need to be replaced.

NOTE:

1.  The  on/off  switch  must  be  in  the  “OFF” 

position in order to charge the unit.

2.  If  the  appliance  has  never  been  used  or 

has  been  stored  for  an  extended  period 

of  time  without  use  -  it  will  take  several 

complete  charge  and  discharge  cycles 

to fully charge the batteries for maximum 

performance.

3

Charging 

Jack

Fig/3.1

Summary of Contents for Sirit VR300

Page 1: ...r Terminals 6 Charging Jack 7 Grill 8 On Off Power Switch 9 Charging Light 10 Dust Cup Release Button 11 Dust Cup container 12 Suction Inlet 13 Brush Bar Window 14 Brush Bar 15 Motor Fan Grill 16 Filter Adapter 17 Dust Cup Filter 18 Transformer 19 Crevice Tool 20 Crevice Tool Storage Compartment Illustrations may differ from actual product NOTE Your cordless vacuum is supplied with the batteries u...

Page 2: ...id such as lemon juice or vinegar If the liquid gets into the eyes flush immediately with clean water for a minimum of 10 minutes and seek medical attention 21 Use only on dry indoor surfaces 22 Do not use for any purpose other than described in this user s guide 23 Do not attempt to use the charger with any other product nor attempt to charge this product with another charger Use only the charger...

Page 3: ...ts in Australia and New Zealand For the nearest Service Agent please call VAXCARE or visit www vax com au 6 2 Assembly NOTE Ensure that the unit is not connected to the charger before assembling the handle 1 Align the t e l e s c o p i c tube on the handle with the opening on the power unit housing Fig 2 1 2 Slide the telescopic tube into the opening until it is seated firmly into position 3 Push ...

Page 4: ...r unit hand vac receptacle place the bottom of the power unit hand vac into the receptacle first then tilt towards the power unit housing until it audibly clicks into place 5 Using the Vacuum NOTE The floor brush will not function without the power unit hand vac in place and fully charged The vacuum is ideal for cleaning stairs and awkward areas 1 Ensure that the power unit hand vac is in position...

Reviews: