operation

4. How to Operate

Turn the vacuum cleaner on by pressing the on/off switch
located on the lower right side of the cleaner (Fig.4/1).

The cleaner can be turned off by pressing the on/off
switch again.

Adjusting the Angle of the Main Body

To adjust the angle of the vacuum cleaner body, push the
recline pedal on the lower left side of the cleaner (Fig.4/2).
Move the handle to the desired position. (A) for
upright position, (B) for normal operation and (C) to clean
under furniture (Fig.4/2).

Brushbar Height Adjuster

The front of the vacuum cleaner has a brushbar height
adjuster that raises and lowers the brushbar to suit the
type of carpet. With the cleaner NOT connected to the
electrical outlet, and when the vacuum is in the upright
position set the adjustment to the lowest setting for
maximum cleaning. If the cleaner is difficult to move, push
the knob to the next highest setting until the vacuum is
comfortable to push. The brushbar must reach the carpet
for effective cleaning.(Fig.4/3).

IMPORTANT

: When the vacuum cleaner is stood in

the upright position or when using the hose and

tools, the brushbar height adjuster must be set to the
highest position.

WARNING:

To avoid injury, keep loose clothing, hair,

fingers and all other parts of the body away from

any moving part (such as the brushbar). Turn off the
switch and unplug the cleaner before adjusting the
cleaner for the carpet height.

On/ off
switch

Fig.4/1

Fig.4/2

Fig.4/3

!

!

A

B

C

WARNING:

This cleaner has a constantly

rotating brushbar which, when left in contact

with lino, parquet and other hard flooring could
potentially cause some damage to the floor surface.

NOTE:

Vax recommends that you raise the height of

the brushbar when using this cleaner on lino and hard
flooring. Vax cannot be held responsible for damage to
these surfaces if the customer fails to take notice of
this recommendation.

!

press
here

Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308

VEU-104 & VEU-105 UG V1.0.qxd:V1.0

5/9/11

09:55  Page 5

Summary of Contents for essentials VEU-104

Page 1: ...ich when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brushbar when using this cleaner on lino and hard flooring Vax cannot be held responsible for damage to these surfaces if the customer fails to take notice of this recommendation Vax Careline UK 0844 412 8455 ROI 1 800 928 ...

Page 2: ...ng screws 22 TurboTool Some models only 1 2 14 15 16 10 5 12 13 22 22 17 6 9 3 4 7 8 20 21 WARNING This cleaner has a constantly rotating brushbar which when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brushbar when using this cleaner on lino and hard flooring Vax cannot be h...

Page 3: ... cigarette butts matches or any hot smoking or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 13 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 14 Do not vacuum up hard or sharp objects such as glass nails screws coins etc 15 Do not use without the fi...

Page 4: ...e dirt container push the top in place there will be an audible click when it is secure Fig 3 3 Assembly of the Hose Align the tabs on the lower hose inspection tube with the slots on the hose Push and turn the hose clockwise until secure Fig 3 4 Wrap the hose round and through the hose clip and then down and insert into hose connector Fig 3 5 Cord Storage This vacuum cleaner is equipped with a co...

Page 5: ...ting until the vacuum is comfortable to push The brushbar must reach the carpet for effective cleaning Fig 4 3 IMPORTANT When the vacuum cleaner is stood in the upright position or when using the hose and tools the brushbar height adjuster must be set to the highest position WARNING To avoid injury keep loose clothing hair fingers and all other parts of the body away from any moving part such as t...

Page 6: ...er in place To remove the dirt container press the dirt container release button and lift away from the vacuum cleaner Fig 6 1 Cleaning the HEPA Filter Remove the dirt container lid by grasping the dirt container and turning anti clockwise Fig 6 2 Empty all the dirt from the container Remove the filter by twisting anti clockwise and pulling out Firmly tap clean the HEPA filter until no more dust i...

Page 7: ...t the dirt container is fully dry before putting back on the vacuum cleaner Do not wash in dishwasher 7 Maintenance Cleaning and Changing the Belt TOOLS REQUIRED Phillips screwdriver WARNING To reduce the risk of electric shock the power cord must be disconnected before removing the dirt container HEPA filter changing the filters or performing maintenance troubleshooting checks Occasionally the po...

Page 8: ...won t run Cause Not properly plugged into electrical outlet Solution Plug in securely Cause No electricity in the electrical outlet Solution Check fuse or breaker Cause On off switch not turned on Solution Push on off switch to on Cause Motor thermostat has tripped Solution Switch off and unplug the vacuum cleaner Leave for one 1 hour before switching the vacuum cleaner back on Cause Blown fuse tr...

Page 9: ...visit vax co uk 10 Consumables To purchase spares and accessories please visit vax co uk HEPA filter kit 1 9 126184 00 11 Technical Specification Voltage 220 240V 50Hz Wattage 1800 1900W varies by model Capacity 3L approx Filters Pleated paper HEPA filter HEPA anti bacterial some models only Cord length 7 5m approx Weight 6 7 6 9kg varies by model Subject to technical change without notice 9 uk se...

Page 10: ...10 This page has been left intentionally blank vax co uk VEU 104 VEU 105 UG V1 0 qxd V1 0 5 9 11 09 55 Page 10 ...

Page 11: ...11 This page has been left intentionally blank Vax Careline UK 0844 412 8455 ROI 1 800 928 308 VEU 104 VEU 105 UG V1 0 qxd V1 0 5 9 11 09 55 Page 11 ...

Page 12: ... EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website vax co uk VEU 104 VEU 105 UG V1 0 qxd V...

Reviews: