Vax Careline

0870 606 1248

safety information

2. Safety Information

For Household Use Only

When using the vacuum cleaner, basic safety precautions
should always be observed, including the following:

1.

Only use the vacuum cleaner indoors on dry
surfaces.

2.

Turn off the vacuum cleaner controls before
connecting or disconnecting from the mains supply.

3.

Always unplug the vacuum cleaner before
connecting or disconnecting the vacuum hose and
accessories.

4.

Children should be supervised to ensure that they
do not play with the appliance.

5.

This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.

6.

Use only as described in this manual.
Use only the manufacturer’s recommended
attachments.

7.

Do not use the vacuum cleaner if it has been
dropped, damaged, left outdoors or dropped into
water. Do not use the vacuum cleaner with a
damaged cord or plug. If the supply cord or plug is
damaged, return the vacuum cleaner to a Vax
Authorised Service Agent or suitably qualified
person for examination, repair or adjustment.

8.

Do not pull or carry by the cord. Do not use the cord
as a handle, close a door on the cord or pull the cord
around sharp edges or corners. Do not run the
vacuum cleaner over the cord. Keep the cord away
from heated surfaces.

9.

Do not handle the plug or vacuum cleaner with wet
hands. Do not use outdoors or on wet surfaces.

10. Do not put any objects into openings. Do not use

with any openings blocked and do not restrict air
flow. Keep all openings free of dust, lint, hair or
anything that may reduce airflow.

11. Keep hair, loose clothing, fingers and all parts of the

body away from openings and moving parts.

12. Do not pick up hot coals, cigarette butts, matches or

any hot, smoking or burning objects.

13. Do not pick up flammable or combustible materials

(lighter fluid, petrol, kerosene, etc) or use in the
presence of explosive liquids or vapours.

14. Do not vacuum up harmful or toxic material (chlorine

bleach, ammonia, drain cleaner, etc).

15. Do not vacuum up hard or sharp objects such as

glass, nails, screws, coins, etc.

16. Do not use without the filters in place.

17. Take extra care when vacuuming on stairs.

18. Keep vacuuming area well lit.

19. Store the vacuum cleaner indoors in a cool, dry area.

20. Turn off the on/off switch before unplugging the

vacuum cleaner.

21. Use only CE-approved 13 amp extension cords. Non-

approved extension cords may overheat. Care should
be taken to arrange the cord so that the cord cannot
be pulled or tripped over.

WARNING:

Always switch off and unplug the

vacuum cleaner from the electrical outlet

before assembling, opening or emptying the dirt
container, or before connecting/disconnecting the
attachments.

CAUTION:

The vacuum cleaner is a very powerful

unit. Before plugging the cord into the electrical

outlet, make sure the switch is in the ‘off’ position. Hold
the vacuum cleaner firmly when starting and in use.

IMPORTANT:

If the inlet, hose or telescopic tube is

blocked, switch off the vacuum cleaner and

remove the blockage(s) before re-starting the vacuum
cleaner.

IMPORTANT:

Washing filters improves vacuum

performance. Make sure all the filters are

completely dry before inserting back into the vacuum
cleaner.

This vacuum cleaner is intended for household use only
and not for commercial or industrial use.

Motor Thermostat

IMPORTANT:

The motor is equipped with a

thermal cut-out. If for any reason, the vacuum

cleaner should over-heat, the thermostat will
automatically turn the unit off. Should this occur,
unplug the vacuum cleaner from the electrical outlet
and turn off the switch. Remove the dirt container
and empty. Clean the filters. Allow the cleaner to cool
for approximately one (1) hour. To re-start, plug into
an electrical outlet and switch back on.

!

!

!

!

!

C91-M4 Series User Guide.qxd:Vax VZL-7015(AT) User Guide  23/3/09  10:19  Page 3

Summary of Contents for C91-M4 Series

Page 1: ...cleaner Always fully extend the mains cable before use Retain for future reference Vax careline 0870 6061248 instruction manual Bagless cylinder Vax model number C91 M4 Series C91 M4 Series User Guid...

Page 2: ...ner handle carry handle 5 Dirt container release button 6 Auto cord rewind 7 On off button 8 Plug 9 Post motor filter cover 10 Wheel Accessories 11 2 in 1 tool 12 Crevice tool 13 Telescopic tube 14 Tu...

Page 3: ...ches or any hot smoking or burning objects 13 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 14 Do not vacuu...

Page 4: ...the TurboBrush to the end of the extension tube For vacuuming large carpeted areas Hard Floor Cleaning Attach the hard floor tool to the end of the extension tube For vacuuming parquet and laminate c...

Page 5: ...inlet 6 Dirt Container Filters Removal Replacement IMPORTANT Vax recommends cleaning the filters everytime the dirt container is emptied for consistent cleaning performance of your machine IMPORTANT A...

Page 6: ...ter from the fabric cassette Each filter can be tapped against the side of a dust bin to remove excess dirt and dust Fig 6 6 The pre motor filters may be rinsed in warm water max 40 C Allow to air dry...

Page 7: ...isk of electric shock the power cord must be disconnected before performing maintenance troubleshooting checks 1 Turn the vacuum cleaner off and unplug from the electrical outlet 2 The flexible hose a...

Page 8: ...slots on front of tool Pivot bottom plate down and snap closed Fig 7 3 8 Storage IMPORTANT Always unplug the vacuum cleaner from the electrical outlet and rewind the power cord as directed before sto...

Page 9: ...ged filters Solution Remove clean and replace filters PROBLEM Accessories won t pick up Cause TurboBrush TurboTool is clogged Solution Refer to section 7 Cause Hose stretch hose is not installed corre...

Page 10: ...tres approx Filters Cyclone separator wipe clean Pre motor filter washable HEPA Post motor filter Anti bacterial exhaust on C91 M4 P only washable Cord Length 6 0m approx Weight 8 55Kg approx Subject...

Page 11: ...Vax Careline 0870 606 1248 This page has been left intentionally blank 11 C91 M4 Series User Guide qxd Vax VZL 7015 AT User Guide 23 3 09 10 19 Page 11...

Page 12: ...ctive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Autho...

Reviews: