MANUAL OF THERMOSTAT XW40L 

 

  

 Please read this manual before using 

 

1.AVERTISSEMENT 

 

Warning: disconnect all electrical connections before 
any kind of maintenance. 

 

The instrument must not be opened.

 

 

In case of failure or faulty operation send the instrument 
back to the distributor or to 

 with a 

detailed description of the fault. 

 

2.DESCRIPTION 

Model 

XW40L

 is microprocessor based controllers suitable 

for applications on medium or low temperature refrigerating 
units. They are provided with 3 relay outputs to control 
compressor, defrost - which can be either electrical or hot gas  
- and the lights. They are also provided with 1 NTC or PTC 
probe inputs, for temperature control. 

The regulation is performed according to the temperature 

measured by the thermostat probe with a positive differential 
from the set point: if the temperature increases and reaches set 
point plus differential the compressor is started and then turned 
off when the temperature reaches the set point value again. 

 

3.KEYBOARD 

 

 

 

 

To display and modify target set point; in 
programming mode it selects a parameter or confirm 
an operation. 
By holding it pressed for 3s when max or min 
temperature is displayed it will be erased. 

 

To see the max. stored temperature; in programming 
mode it browses the parameter codes or increases the 
displayed value. By holding it pressed for 3s the fast 
freezing cycle is started. 

 

To see the min stored temperature; in programming 
mode it browses the parameter codes or decreases the 
displayed value. 

 

By holding it pressed for 3s the defrost is started. 

 

Switch ON and OFF the light of the cold-room. 

 

Switch ON and OFF the instrument. 

 

KEY COMBINATIONS 

 + 

 

To lock and unlock the keyboard. 

 + 

 

To enter the programming mode. 

 + 

 

To exit the programming mode. 

 

3.1 To lock and unlock the keyboard 

 

HOW TO LOCK THE KEYBOARD 

 

Keep the 

 and the 

 keys together for more 

than 3 s. The "POF" message will be displayed and 
the keyboard is locked. At this point it is only 
possible the viewing of the set point or the MAX or 
Min temperature stored and to switch ON and OFF 
the light, the auxilary output and the instrument. 

 

HOW TO UNLOCK THE KEYBOARD 

 

Keep the 

 and the 

 keys pressed together for 

more than 3 s. The "POn" message will be displayed 
and the keyboard is unlocked. 

 

3.2 Meaning of the LED 

Each LED function is described in the following table : 

 

LED MODE 

FONCTION 

 

ON 

The compressor is running 

 

Flashing 

Programmation phase ( flashing with  ) 
Anti-short cycle delay enabled 

 

ON 

The fan is running. 

 

Flashing  Programmation phase ( flashing with  ) 

 

ON 

The defrost is enabled. 

 

Flashing  Drip time in progress 

  ON 

The fast freezing cycle is enable 

 

ON 

Alarm signal 
In “Pr2” indicates that the parameter is also 
present in “Pr1 

  ON 

The light is on 

 

3.3 How to see the min temperature 

 

Press and release the 

n

 key. 

The “Lo” message will be displayed followed by the 
minimum temperature recorded. 
By pressing the 

n

 key or waiting for 5s the normal 

display will be restored. 

 

3.4 How to see the max temperature 

 

Press and release the 

o

 key. 

The “Hi” message will be displayed followed by the 
maximum  temperature recorded. 
By pressing the 

o

 key or waiting for 5s the normal 

display will be restored. 

 

3.5 How to reset the max and min temperature 
recorded 

To reset the stored temperature, when max or min temperature 
is displayed, press SET key until “rST” label starts blinking. 

N.B. : After the installation RESET the temperature 
stored . 

 

3.6 How to see and modify the set point 

 

Push and immediately release the 

SET 

key: the 

display will show the Set point value. 
The SET LED start blinking. 
To change the Set value push the 

 

or 

 arrows 

within 10s. 
To memorise the new set point value push the 

SET

 

key again or wait 10s. 

 

3.7 To start a manual defrost 

 

Push the 

DEF 

key for more than 2 seconds and a 

manual defrost will start. 

 

3.8 To enter in parameters list Pr1 

To enter the parameter list “Pr1” (user accessible parameters) 
operate as follows: 

 

Enter the Programming mode by pressing the 
Set and DOWN key for few seconds (

 and   

start blinking). 
The instrument will show the first parameter 
present in “Pr1”. 

Summary of Contents for REVERSO

Page 1: ...igerating diagrams page 3 Manual of the thermostat page 4 6 Spare parts page 7 Rue Charles Hermite Z I des Sables BP 59 54110 Dombasle sur Meurthe France tel 33 03 83 45 82 82 fax 33 03 83 45 82 93 e mail commercial vcs vauconsant com export vauconsant com REVERSO ...

Page 2: ...ing the standard of unit the twist of the self evaporating tray can be situed in the face or in the back of the unit Astainless steel sheet deflector located in the self evaporating tray allow to direct the water vapour The sheet must be located in the middle of the self evaporating tray the same distance in each side The deflector must be located to have the good direction of the inclination like...

Page 3: ...ter Cd Condensor Sn Level probe D Relief valve St Atmosphere temperature probe Dh Drier Tb Safety thermostat for self evaporating tray E Evaporator Tf Fluorescent tub I 4 positions switch Tr Thermostat XR40 Kb Self evaporating tray relay Ts Safety Thermostat Kd Defrost relay V Well ventilator Lh Halogen lamp Va Variator Q Fuse holder Vc Condensor fan R Heating element ...

Page 4: ...ed At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light the auxilary output and the instrument HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s The POn message will be displayed and the keyboard is unlocked 3 2 Meaning of the LED Each LED function is described in the following table...

Page 5: ...t message is displayed for about 3s 4 1 EE alarm The instruments are provided with an internal check for the data integrity Alarm EE flashes when a failure in the memory data occurs In such cases the alarm output is enabled 4 2 Alarm recovery Probe alarms P1 probe1 faulty P2 they automatically stop 10s after the probe restarts normal operation Check connections before replacing the probe Temperatu...

Page 6: ...ital input ON ALARM signal In Pr2 indicates the parameter is also present in Pr1 3 2 To see the set point Push and release the SET key to see the Set point value To come back to the normal display push again the SET key or wait 10s 3 3 To change the set point Hold pushed the SET key for 3s to change the Set point value The value of the set point will be displayed and the LED1 2 start blinking To c...

Page 7: ...stance with blades length 625 mm power 1250 W X 12 2518 Evaporator length 580 X 12 2520 Evaporator length 900 X 12 2522 Evaporator length 1230 X 12 2524 Evaporator length 1550 X Option crawl heating halogen 06 0622 Halogen lamp power 200W X X X X 06 0620 Aluminium reflector X X X X 06 0625 Protective glass fixing X X X X 06 1520 Variator X X X X Lighting 06 1005 Orange indicator switch X X X X 06 ...

Reviews: