Maintenance
Always remember to
switch off
the appliance by opening the fuse holder before any
maintenance operations.
•
Bain-marie well:
Lift the well from the unit, the well’s
heating
elements
are
accessible
by
dismantling
the
removable
strip
then
removing the glasswool.
•
Ventilated heat cupboard:
The heating module is placed on the heat cupboard's ceiling. To dismantle it, remove the 4
mounting screws fixing it to the ceiling. The ventilator is fixed by 3 screws, the heating elements are
fixed by 2 nuts, use a Ø19 flat spanner to remove them.
Casing
Heating elements
casing
Well
Heating elements
Ventilation deflector
Heating
elements fixing
sheet
Heating elements sheet
support
Ventilator support
Heating elements
Ventilator